A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Detection and quantification of HBV and HCV in plasma samples by means of different molecular assays: Comparative study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Viral load is a very useful marker for monitoring patients infected with HBV and HCV. This work compares assays based on transcription-mediated amplification (TMA) and on real-time PCR (RT-PCR) to verify whether they can be interchangeable.

Material And Methods: A bicentric study, in which 147 plasma samples from patients infected with HBV and 229 with HCV were analyzed, was carried out. TMA-based assays (Aptima® HBV Quant and Aptima® HCV Quant Dx, employing Panther system (Hologic®)) and RT-PCR (COBAS® AmpliPrep/COBAS® TaqMan® and COBAS® 6800) were used and the degree of concordance between them was calculated.

Results: Viral load was detected in both systems in 60 (40.82%) HBV samples (median log viral load: COBAS: 2.51IU/mL (IQR 2.20-3.17), Panther: 2.71IU/mL (IQR 2.21-3.22)) and in 39 (16.96%) HCV samples (median log viral load: COBAS: 3.93IU/mL (IQR 2.24-6.01), Panther: 3.80IU/mL (IQR 1.99-6.14)). The agreement between both systems was κ=0.943 for HBV and κ=0.925 for HCV. Comparison of viral load samples detected by both assays showed a hight correlation for HBV (R=0.86) and for HCV (R=0.97).

Conclusions: Both TMA and RT-PCR based assays may be interchangeable for the management of patients infected with HBV and HCV.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.eimce.2022.12.007DOI Listing