A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A New Reactor Concept for Single-Chamber Microbial Fuel Cells and Possible Anti-Fouling Strategies for Long-Term Operation. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Microbial fuel cells are a promising technology for future wastewater treatment, as it allows cleaning and power generation simultaneously. The bottleneck of microbial fuel cells is often its cathodes because they determine the power output. Gas diffusion electrodes might overcome this bottleneck due to their low production costs and high oxygen reduction rates. However, biofilm formation on the gas diffusion electrodes reduces their performance over time. In this work, a new reactor design of the microbial fuel cell using rotating gas diffusion electrodes is presented. The biofilm growth on the electrode during operation was observed and its effect on the performance of the microbial fuel cell was examined. In addition, different antifouling strategies were investigated over a period of 80 days. It was found that already after 7 days of operation a complete biofilm had grown on an untreated gas diffusion electrode. However, this does not seem to affect the performance of the cells in the beginning. Differences in the performance of the reactors with and without an antifouling strategy only become apparent from day 15 onwards. The use of UV radiation and antibacterial membranes leads to the best results with maximum power densities of approx. 200 mW m while the untreated microbial fuel cell only achieves a maximum power density of approx. 20 mW m.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9784785PMC
http://dx.doi.org/10.3390/microorganisms10122421DOI Listing

Publication Analysis

Top Keywords

microbial fuel
24
gas diffusion
16
fuel cells
12
diffusion electrodes
12
fuel cell
12
maximum power
8
microbial
6
fuel
6
reactor concept
4
concept single-chamber
4

Similar Publications