Clinical and Radiological Outcomes after Total Shoulder Arthroplasty Using Custom-Made Glenoid Components: A Systematic Review.

J Clin Med

Department of Orthopedic Surgery, Ordensklinikum Linz Barmherzige Schwestern, Vinzenzgruppe Center of Orthopedic Excellence, Teaching Hospital, Paracelsus Medical University Salzburg, 4020 Linz, Austria.

Published: December 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Reverse total shoulder arthroplasty presents itself sometimes as challenging when it comes to addressing massive bone loss, either in primary or revision settings. Custom components recently have made their way into shoulder prosthetics and are meant to help in the case of extensive glenoid bone destruction. Because of strict indication and the fairly recent introduction of these implants, the usage of custom-made glenoid implants is not very common yet. However, the early results are promising. The purpose of this review was to summarize and analyze the available literature. Therefore, a systematic review was performed according to PRISMA guidelines. A comprehensive search of the databases PubMed, Cochrane, and Livivo was performed to screen for studies reporting on clinical and radiological outcomes of custom glenoid implants. Four studies with a total of 46 shoulders were included in this review. The mean patient age was 68.8 years and the mean time of follow-up was 24.3 months. The weighted means showed an increase in CMS (32.7 points), in ASES (39.8 points), in anteversion (67.4 degrees), and in abduction (51.9 degrees) and a decrease in VAS (5.4 points). Custom-made glenoid implants are therefore a viable option in cases of large combined glenoid bone loss, both in primary and revision shoulder arthroplasty.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9782147PMC
http://dx.doi.org/10.3390/jcm11247268DOI Listing

Publication Analysis

Top Keywords

shoulder arthroplasty
12
custom-made glenoid
12
glenoid implants
12
clinical radiological
8
radiological outcomes
8
total shoulder
8
systematic review
8
bone loss
8
loss primary
8
primary revision
8

Similar Publications

A 2-year minimum follow-up period has generally been preferred in orthopaedic studies. This minimum standard aids comparisons across the literature and helps to ensure methodological rigor. However, in some situations these minimum durations are not required to answer specific research questions and strictly enforcing these requirements poses unnecessary barriers to research by adding cost and complexity, increasing the risk of loss to follow-up, and potentially restricting early dissemination of clinically important findings.

View Article and Find Full Text PDF

Introduction: Reverse total shoulder arthroplasty is a well-established treatment for patients with rotator cuff tear arthropathy. The outcome after reverse total shoulder arthroplasty has been investigated in several studies and national registries. However, the treatment has not been compared to non-surgical treatment.

View Article and Find Full Text PDF

Objective: The incidence of total shoulder arthroplasty (TSA) in the United States continues to climb as an aging yet active population increases demand for the procedure. Due to promising clinical results out of Europe, improvement in prosthesis design, and wider acceptance of reverse total shoulder arthroplasty (rTSA), this study was designed to evaluate how rTSA and anatomical TSA (aTSA) utilization, patient selection, and length of stay have changed at a single institution.

Methods: This was a retrospective cohort study of patients from one hospital system between 2017 and 2023.

View Article and Find Full Text PDF

Background: This study aimed to evaluate how subscapularis tendon repair influences joint loads in relation to humeral offset and arm position.

Patients And Methods: Two fresh-frozen, whole-body cadaveric shoulders underwent a reverse total shoulder arthroplasty (rTSA) on the humeral side using an internal proprietary load-sensing system (LSS) (Goldilocks, Statera Medical, Montreal, Canada). In addition to three "complex" Activity Daily Life positions ("behind the back", "overhead reach", and "across the chest"), four standard postures (external rotation, extension, abduction, and flexion) were used to record the glenohumeral loads (Newtons) and their locations applied to the implant.

View Article and Find Full Text PDF

Introduction/objectives: Irreparable subscapularis tears can cause severe functional impairment and present significant clinical challenges. Current treatment options include tendon transfers (TTs), anterior capsular reconstruction, and reverse shoulder arthroplasty. Each approach has distinct biomechanical advantages and limitations, but there remains no consensus regarding the optimal treatment.

View Article and Find Full Text PDF