A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Human-prosthesis cooperation: combining adaptive prosthesis control with visual feedback guided gait. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Personalizing prosthesis control is often structured as human-in-the-loop optimization. However, gait performance is influenced by both human control and intelligent prosthesis control. Hence, we need to consider both human and prosthesis control, and their cooperation, to achieve desired gait patterns. In this study, we developed a novel paradigm that engages human gait control via user-fed visual feedback (FB) of stance time to cooperate with automatic prosthesis control tuning. Three initial questions were studied: (1) does user control of gait timing (via visual FB) help the prosthesis tuning algorithm to converge faster? (2) in turn, does the prosthesis control influence the user's ability to reach and maintain the target stance time defined by the feedback? and (3) does the prosthesis control parameters tuned with extended stance time on prosthesis side allow the user to maintain this potentially beneficial behavior even after feedback is removed (short- and long-term retention)?

Methods: A reinforcement learning algorithm was used to achieve prosthesis control to meet normative knee kinematics in walking. A visual FB system cued the user to control prosthesis-side stance time to facilitate the prosthesis tuning goal. Seven individuals without amputation (AB) and four individuals with transfemoral amputation (TFA) walked with a powered knee prosthesis on a treadmill. Participants completed prosthesis auto-tuning with three visual feedback conditions: no FB, self-selected stance time FB (SS FB), and increased stance time FB (Inc FB). The retention of FB effects was studied by comparing the gait performance across three different prosthesis controls, tuned with different visual FB.

Results: (1) Human control of gait timing reduced the tuning duration in individuals without amputation, but not for individuals with TFA. (2) The change of prosthesis control did not influence users' ability to reach and maintain the visual FB goal. (3) All participants increased their prosthesis-side stance time with the feedback and maintain it right after feedback was removed. However, in the post-test, the prosthesis control parameters tuned with visual FB only supported a few participants with longer stance time and better stance time symmetry.

Conclusions: The study provides novel insights on human-prosthesis interaction when cooperating in walking, which may guide the future successful adoption of this paradigm in prosthesis control personalization or human-in-the-loop optimization to improve the prosthesis user's gait performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9753428PMC
http://dx.doi.org/10.1186/s12984-022-01118-zDOI Listing

Publication Analysis

Top Keywords

prosthesis control
44
stance time
36
prosthesis
18
control
16
visual feedback
12
gait performance
12
stance
9
time
9
visual
8
gait
8

Similar Publications