Evaluation of the biocompability and corrosion activity of resorbable CaMgZnYbBAu alloys.

Sci Rep

Department of Engineering Materials and Biomaterials, Faculty of Mechanical Engineering, Silesian University of Technology, Konarskiego 18a, 44-100, Gliwice, Poland.

Published: December 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Calcium-based alloys can be promising candidates for use as biodegradable implants because of attractive properties as mechanical, corrosive, and biocompatible. In the work, the biocompatibility authors discussed the results of the CaMgZnYbB (x = 0, 1, 2, 3 at.%) and CaMgZnYbBAu (x = 1, 2 at.%) alloys. The tests were performed using a MTT assay. The corrosion behavior of such Ca-based alloys in PWE fluid at 37 °C was studied and compared with the results in Ringer's solution from previous works. Electrochemical tests were presented by open circuit potential and potentiodynamic curves. Different concentrations of boron and gold in the alloys caused changes in the corrosion results. The best corrosion resistance in PWE solution was observed for the Ca-based alloy with 2 at.% Au due to the lowest value of the corrosion current density (j), equal to 10.6 µA·cm. A slightly higher value of j was obtained for the CaMgZnYbB alloy with the lowest roughness values. The results of the cytotoxicity tests also showed that the alloy with 3 at.% boron was characterized by the highest cell viability. The investigation results discussed in the work allow us to suggest that the presented calcium alloys with 3 at.% of B, and 2 at.% of Au addition may be promising materials for the use in implantology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9722665PMC
http://dx.doi.org/10.1038/s41598-022-25069-6DOI Listing

Publication Analysis

Top Keywords

alloy at%
8
alloys
6
at%
6
corrosion
5
evaluation biocompability
4
biocompability corrosion
4
corrosion activity
4
activity resorbable
4
resorbable camgznybbau
4
camgznybbau alloys
4

Similar Publications

Statement Of Problem: Despite high survival rates of implant-supported single crowns, retention loss remains common and decementation of crowns can compromise long-term stability, patient satisfaction, and treatment costs. Limited long-term evidence on cement type, abutment design, and materials requires further research to optimize clinical outcomes.

Purpose: The aim of this retrospective clinical study was to analyze the survival and decementation rates of zirconia and metal-ceramic implant-supported crowns in combination with different abutments (prefabricated or custom and unabraded or airborne-particle abraded).

View Article and Find Full Text PDF

Background: Previous trials have demonstrated increased 5-year risks for adverse clinical events after coronary artery implantation of poly-l-lactic acid-based bioresorbable scaffolds (BRS) compared with cobalt chromium (CoCr) everolimus-eluting stents (EES).

Objectives: The aim of this study was to evaluate the 5-year clinical outcomes of the novel sirolimus-eluting NeoVas BRS compared with CoCr EES.

Methods: A total of 560 patients with single de novo native coronary artery lesions with reference vessel diameter 2.

View Article and Find Full Text PDF

Introduction: This study evaluated the fatigue resistance of two Nickel-titanium (NiTi) engine-driven file systems with identical geometries and different heat treatments tested under static and dynamic conditions in simulated root canals.

Methods: Cyclic fatigue tests were conducted using ProTaper Universal (PTU) and ProTaper Gold (PTG) instruments with a curvature of 35° and a radius of 6 mm in both static and dynamic modes at body temperature using a customized cyclic fatigue testing device. The number of cycles to fracture (NCF) was recorded.

View Article and Find Full Text PDF

In the present work, DFT investigations were carried out to study the effect of doping on the structural, mechanical, and optical properties of a quaternary High Entropy Alloy (HEA), FeCoVNi, with substitution doping of Co and Ni elements by Se. The cubic phase of FeCoVNi transforms into an orthorhombic phase when Co and Ni sites are replaced with Se. The mechanical stability is retained for substitution of Co up to 37.

View Article and Find Full Text PDF