Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The possibility to record proteomes in high throughput and at high quality has opened new avenues for biomedical research, drug discovery, systems biology, and clinical translation. However, high-throughput proteomic experiments often require high sample amounts and can be less sensitive compared to conventional proteomic experiments. Here, we introduce and benchmark Zeno SWATH MS, a data-independent acquisition technique that employs a linear ion trap pulsing (Zeno trap pulsing) to increase the sensitivity in high-throughput proteomic experiments. We demonstrate that when combined with fast micro- or analytical flow-rate chromatography, Zeno SWATH MS increases protein identification with low sample amounts. For instance, using 20 min micro-flow-rate chromatography, Zeno SWATH MS identified more than 5000 proteins consistently, and with a coefficient of variation of 6%, from a 62.5 ng load of human cell line tryptic digest. Using 5 min analytical flow-rate chromatography (800 µl/min), Zeno SWATH MS identified 4907 proteins from a triplicate injection of 2 µg of a human cell lysate, or more than 3000 proteins from a 250 ng tryptic digest. Zeno SWATH MS hence facilitates sensitive high-throughput proteomic experiments with low sample amounts, mitigating the current bottlenecks of high-throughput proteomics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9711518PMC
http://dx.doi.org/10.7554/eLife.83947DOI Listing

Publication Analysis

Top Keywords

zeno swath
24
proteomic experiments
16
high-throughput proteomic
12
sample amounts
12
high-throughput proteomics
8
trap pulsing
8
analytical flow-rate
8
flow-rate chromatography
8
chromatography zeno
8
low sample
8

Similar Publications

Bridging Targeted (Zeno MRM-HR) and Untargeted (SWATH) LC-HRMS in a Single Run for Sensitive Exposomics.

Anal Chem

August 2024

Department of Food Chemistry and Toxicology, Faculty of Chemistry, University of Vienna, 1090 Vienna, Austria.

Traditionally, chemical exposure has been assessed by low-resolution mass spectrometry via targeted approaches due to the typically extremely low concentration of such compounds in biological samples. Nevertheless, untargeted approaches are now becoming a promising tool for a broader investigation of the exposome, covering additional compounds, their biotransformation products, and possible metabolic alterations (metabolomics). However, despite broad compound coverage, untargeted metabolomics still underperforms in ultratrace biomonitoring analysis.

View Article and Find Full Text PDF

Improving Proteomic Identification Using Narrow Isolation Windows with Zeno SWATH Data-Independent Acquisition.

J Proteome Res

August 2024

Department of Pharmaceutical Microbiology, Graduate School of Pharmaceutical Sciences, Kumamoto University, 5-1 Oe-honmachi, Chuo-ku, Kumamoto 862-0973, Japan.

Article Synopsis
  • * With the optimized narrow SWATH (nSWATH), researchers identified significantly more protein groups—5916 from mouse liver and 7719 from HEK293T cells—showing improvements of 7.52% and 4.99% respectively over conventional SWATH.
  • * nSWATH also demonstrated enhanced accuracy and precision, identifying an average of 95,456 precursors and 9342 protein groups in benchmark samples, achieving up to 40.7% more protein group identifications at lower loading amounts.
View Article and Find Full Text PDF

High-Throughput Proteomics and Phosphoproteomics of Rat Tissues Using Microflow Zeno SWATH.

J Proteome Res

July 2024

ProCan®, Children's Medical Research Institute, Faculty of Medicine and Health, The University of Sydney, Westmead, New South Wales 2145, Australia.

High-throughput tissue proteomics has great potential in the advancement of precision medicine. Here, we investigated the combined sensitivity of trap-elute microflow liquid chromatography with a ZenoTOF for DIA proteomics and phosphoproteomics. Method optimization was conducted on HEK293T cell lines to determine the optimal variable window size, MS2 accumulation time and gradient length.

View Article and Find Full Text PDF
Article Synopsis
  • DIA (Data-Independent Acquisition) in LC-MS/MS provides better reproducibility and quantitative accuracy in metabolomics and lipidomics research, outperforming traditional Data-Dependent Acquisition (DDA).
  • The combination of DIA with the Zeno trap and Electron-Activated Dissociation (EAD) significantly enhances data quality and allows for better structural identification of compounds in complex samples, as demonstrated in the study of the amphipod Gammarus fossarum.
  • This methodology shows great potential for advancing research in omics fields, especially in characterizing molecular changes and identifying biologically significant features in various organisms.
View Article and Find Full Text PDF

Various types of milk powder purportedly providing diverse health functions have emerged with the growth of the country's elderly population. Some manufacturers illegally add chemical drugs to their products to achieve their reported benefits, which poses a threat to consumer health. The existing standard methods are inapplicable to such complex sample matrices and require testing based on functional claims and classification.

View Article and Find Full Text PDF