A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Shape-Sensing Robotic-Assisted Bronchoscopy vs Digital Tomosynthesis-Corrected Electromagnetic Navigation Bronchoscopy: A Comparative Cohort Study of Diagnostic Performance. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Electromagnetic navigational bronchoscopy has been the dominant bronchoscopic technology for targeting small peripheral lesions and now includes digital tomosynthesis-electromagnetic navigational bronchoscopy (DT-ENB), allowing near-real-time intraprocedural nodule visualization. Shape-sensing robotic-assisted bronchoscopy (ssRAB), with improved catheter stability and articulation recently became available. Although the diagnostic performance of these two methods seems higher than that of legacy systems, data remain limited. We sought to compare the diagnostic yield of these two novel platforms after their introduction at our institution.

Research Question: Does the diagnostic yield of ssRAB differ significantly from that of DT-ENB in patients undergoing biopsy of peripheral pulmonary lesions (PPLs)?

Study Design And Methods: This retrospective comparative cohort study analyzed prospectively collected data on consecutive procedures performed with DT-ENB and ssRAB in their first 6 months of use at our institution. Biopsies were considered diagnostic if histopathologic analysis revealed malignancy or specific benign features that readily explained the presence of a PPL. Nonspecific inflammation, normal lung or airway, and atypia not diagnostic of malignancy were considered nondiagnostic.

Results: SSRAB was used to biopsy 143 PPLs in 133 patients and DT-ENB was used to biopsy 197 PPLs in 170 patients. Diagnostic yield was 77% for ssRAB (110 of 143 PPLs) and 80% (158 of 197 PPLs) for DT-ENB (OR, 0.8; 95% CI, 0.5-1.4; P = .4). Median lesion diameters were 17 and 19 mm, respectively. No difference in diagnostic yield was found after adjustment for lesion size, bronchus sign, peripheral vs middle third location, and sex. Pneumothorax complicated 1.5% of ssRAB and 1.8% of DT-ENB procedures (P = .86).

Interpretation: SSRAB and DT-ENB showed comparable diagnostic yields and safety profiles in this comparative cohort study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chest.2022.10.019DOI Listing

Publication Analysis

Top Keywords

diagnostic yield
16
comparative cohort
12
cohort study
12
diagnostic
9
shape-sensing robotic-assisted
8
robotic-assisted bronchoscopy
8
diagnostic performance
8
navigational bronchoscopy
8
143 ppls
8
197 ppls
8

Similar Publications