Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
The main objective of this study was to explore the changes in bacterial communities and antibiotic resistance genes (ARGs) in an integrated fixed-film activated sludge (IFAS)+magnetic coagulation process wastewater treatment plant (WWTP) in Xinjiang. The bacterial communities and ARGs in the influent, suspended activated sludge, attached biofilm, and effluent were studied using 16S rRNA gene sequencing and metagenomic sequencing. The results showed that the average relative abundances of Chloroflexi and Nitrospirae in activated sludge were 3.50% and 0.03%, respectively, and their relative abundances in biofilm reached 10.02% and 2.12%, respectively. The average removal rates of NH-N and TN increased from 91.89% and 66.76% to 97.71% and 91.90% after the reformation of this wastewater treatment plant, respectively, indicating that IFAS enhanced the biological nitrogen removal capacity of wastewater treatment plants in cold regions. The average relative abundances of and related to iron redox in the biological treatment section were 5.24% and 3.72%, respectively, and the relative abundance of in effluent reached 9.48%, indicating that the magnetic powder had an impact on the bacterial community. The IFAS wastewater treatment plant had an obvious removal effect on ARGs, and the relative abundance of ARGs decreased from 191.08×10‰ in the influent to 32.58×10‰ in the effluent. The relative abundance of ARGs in activated sludge was 63.25×10‰-72.38×10‰, which was significantly higher than 41.31×10‰ in biofilm. However, the relative abundances of dominant subtypes of ARGs such as , , and in biofilm were 5.77×10‰, 2.52×10‰, and 2.03×10‰, respectively, which were higher than the 3.15×10‰-3.57×10‰, 1.73×10‰-2.24×10‰, and 1.28×10‰-1.76×10‰ in activated sludge. The network analysis indicated that and were respectively positively correlated with and . These results can provide theoretical reference for the optimal operation and ARGs control of WWTPs in cold regions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.13227/j.hjkx.202112169 | DOI Listing |