Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Walking cadence (steps/min) has emerged as a valid proxy of physical activity intensity, with consensus across numerous laboratory-based treadmill studies that ≥100 steps/min approximates absolutely defined moderate intensity (≥3 metabolic equivalents; METs). We recently reported that this cadence threshold had a classification accuracy of 73.3% for identifying moderate intensity during preferred pace overground walking in young adults. The purpose of this study was to evaluate and compare the performance of a cadence threshold of ≥100 steps/min for correctly classifying moderate intensity during overground walking in middle- and older-aged adults.
Methods: Participants (N = 174, 48.3% female, 41-85 years of age) completed laboratory-based cross-sectional study involving an indoor 5-min overground walking trial at their preferred pace. Steps were manually counted and converted to cadence (total steps/5 min). Intensity was measured using indirect calorimetry and expressed as METs. Classification accuracy (sensitivity, specificity, accuracy) of a cadence threshold of ≥100 steps/min to identify individuals walking at ≥3 METs was calculated.
Results: The ≥100 steps/min threshold demonstrated accuracy of 74.7% for classifying moderate intensity. When comparing middle- vs. older-aged adults, similar accuracy (73.4% vs. 75.8%, respectively) and specificity (33.3% vs. 34.5%) were observed. Sensitivity was high, but was lower for middle- vs. older-aged adults (85.2% vs. 93.9%, respectively).
Conclusion: A cadence threshold of ≥100 steps/min accurately identified moderate-intensity overground walking. Furthermore, accuracy was similar when comparing middle- and older-aged adults. These findings extend our previous analysis in younger adults and confirm the appropriateness of applying this cadence threshold across the adult lifespan.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/sms.14274 | DOI Listing |