98%
921
2 minutes
20
Early diagnosis and disease phenotyping in COPD are currently limited by the use of spirometry, which may remain normal despite significant small-airways disease and which may not fully capture a patient's underlying pathophysiology. In this study we explored the use of a new non-invasive technique that assesses gas-exchange inhomogeneity in patients with COPD of varying disease severity (according to GOLD Stage), compared with age-matched healthy controls. The technique, which combines highly accurate measurement of respiratory gas exchange using a bespoke molecular flow sensor and a mechanistic mathematical model of the lung, provides new indices of lung function: the parameters σCL, σCd, and σVD represent the standard deviations of distributions for alveolar compliance, anatomical deadspace and vascular conductance relative to lung volume, respectively. It also provides parameter estimates for total anatomical deadspace and functional residual capacity (FRC). We demonstrate that these parameters are robust and sensitive, and that they can distinguish between healthy individuals and those with mild-moderate COPD (stage 1-2), as well as distinguish between mild-moderate COPD (stage 1-2) and more severe (stage 3-4) COPD. In particular, σCL, a measure of unevenness in lung inflation/deflation, could represent a more sensitive non-invasive marker of early or mild COPD. In addition, by providing a multi-dimensional assessment of lung physiology, this technique may also give insight into the underlying pathophysiological phenotype for individual patients. These preliminary results warrant further investigation in larger clinical research studies, including interventional trials.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9659845 | PMC |
http://dx.doi.org/10.3389/fphys.2022.1032126 | DOI Listing |
J Appl Physiol (1985)
July 2023
Department of Physiology, Anatomy and Genetics, University of Oxford, Oxford, United Kingdom.
This study explored the use of computed cardiopulmonography (CCP) to assess lung function in early-stage cystic fibrosis (CF). CCP has two components. The first is a particularly accurate technique for measuring gas exchange.
View Article and Find Full Text PDFRespir Care
September 2023
Pulmonary, Critical Care and Sleep Medicine Division, Department of Medicine, Stony Brook University Medical Center, Stony Brook, New York.
Background: To understand the fate of aerosols delivered by high-flow nasal cannula using continuous nebulization, an open-source anatomical model was developed and validated with a modified real-time gamma ratemeter technique. Mass balance defined circuit losses. Responsiveness to infusion rate and device technology were tested.
View Article and Find Full Text PDFJ Appl Physiol (1985)
February 2023
Evang. Kliniken Essen-Mitte GmbH, Essen, Germany.
Positive airway pressure that dynamically changes with breathing, and clearance of anatomical dead space are the key mechanisms of noninvasive respiratory support with nasal high flow (NHF). Pressure mainly depends on flow rate and nare occlusion. The hypothesis is that an increase in asymmetrical occlusion of the nares leads to an improvement in dead-space clearance resulting in a reduction in re-breathing.
View Article and Find Full Text PDFFront Physiol
October 2022
Oxford NIHR Biomedical Research Centre, University of Oxford, Oxford, United Kingdom.
Early diagnosis and disease phenotyping in COPD are currently limited by the use of spirometry, which may remain normal despite significant small-airways disease and which may not fully capture a patient's underlying pathophysiology. In this study we explored the use of a new non-invasive technique that assesses gas-exchange inhomogeneity in patients with COPD of varying disease severity (according to GOLD Stage), compared with age-matched healthy controls. The technique, which combines highly accurate measurement of respiratory gas exchange using a bespoke molecular flow sensor and a mechanistic mathematical model of the lung, provides new indices of lung function: the parameters σCL, σCd, and σVD represent the standard deviations of distributions for alveolar compliance, anatomical deadspace and vascular conductance relative to lung volume, respectively.
View Article and Find Full Text PDFFront Physiol
April 2022
KK Women's and Children's Hospital, Children's Intensive Care Unit, Singapore, Singapore.
High-frequency oscillatory ventilation (HFOV) is a type of invasive mechanical ventilation that employs supra-physiologic respiratory rates and low tidal volumes (V) that approximate the anatomic deadspace. During HFOV, mean airway pressure is set and gas is then displaced towards and away from the patient through a piston. Carbon dioxide (CO) is cleared based on the power (amplitude) setting and frequency, with lower frequencies resulting in higher V and CO clearance.
View Article and Find Full Text PDF