Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Statement Of Problem: Digital imaging and communications in medicine (DICOM) files together with surface scans must be accurately registered in virtual implant planning software programs to match real-life dimensions and ensure correct plan transfer through computer-aided manufactured surgical guides.
Purpose: The purpose of this in vitro study was to evaluate the accuracy of 3 different registration methods of DICOM data with and without metal restorations and a metal artifact reduction (MAR) tool for surface scans.
Material And Methods: Thirteen dentate mandibles were assigned to each group of this study (n=39). Baseplate wax was adapted to the bone surfaces of each mandible, and 5 radiopaque markers were attached. A desktop scanner was used to obtain control scans. The groups of metal-free mandibles (MFM) and mandibles with metal restorations (MRM) were scanned to obtain DICOM data without a MAR tool. Additional DICOM data for the MRM were obtained with the MAR tool (MRM-MAR). Point-based registration (PBR), best-fit registration (BFR), and automatic registration (AR) were used to align standard tessellation language (STL) and DICOM data, and 3 data sets were exported. Radiographic markers on each data set were compared with those on the control scan, and positional deviations were calculated and statistically evaluated with 1-way ANOVA followed by multiple pairwise comparisons, independent samples t test, and 2-way ANOVA (α=.05).
Results: Within each group, PBR had the lowest deviation values with statistical significance in the MFM and the MRM-MAR groups (P<.001). AR showed failure in the MRM and the MRM-MAR groups. Statistically significant differences were found on comparing the average deviations among the 3 groups for PBR only (P<.001). No association was found between deviation values and the presence or absence of metal restoration, while a positive association was found with the type of registration method (P<.001).
Conclusions: PBR had the highest accuracy level compared with AR and BFR methods. An increase in the number of calculations resulted in more deviation values. The MAR tool had a positive effect on PBR in mandibles with metal restorations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2022.09.017 | DOI Listing |