In radiology and oncology, radiomic models are increasingly employed to predict clinical outcomes, but their clinical deployment has been hampered by lack of standardisation. This hindrance has driven the international Image Biomarker Standardisation Initiative (IBSI) to define guidelines for image pre-processing, standardise the formulation and nomenclature of 169 radiomic features and share two benchmark digital phantoms for software calibration. However, to better assess the concordance of radiomic tools, more heterogeneous phantoms are needed. We created two digital phantoms, called ImSURE phantoms, having isotropic and anisotropic voxel size, respectively, and 90 regions of interest (ROIs) each. To use these phantoms, we designed a systematic feature extraction workflow including 919 different feature values (obtained from the 169 IBSI-standardised features considering all possible combinations of feature aggregation and intensity discretisation methods). The ImSURE phantoms will allow to assess the concordance of radiomic software depending on interpolation, discretisation and aggregation methods, as well as on ROI volume and shape. Eventually, we provide the feature values extracted from these phantoms using five open-source IBSI-compliant software.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9653377 | PMC |
http://dx.doi.org/10.1038/s41597-022-01715-6 | DOI Listing |
Sci Data
November 2022
Medical Physics Department, Veneto Institute of Oncology - IOV IRCCS, Padova, Italy.
In radiology and oncology, radiomic models are increasingly employed to predict clinical outcomes, but their clinical deployment has been hampered by lack of standardisation. This hindrance has driven the international Image Biomarker Standardisation Initiative (IBSI) to define guidelines for image pre-processing, standardise the formulation and nomenclature of 169 radiomic features and share two benchmark digital phantoms for software calibration. However, to better assess the concordance of radiomic tools, more heterogeneous phantoms are needed.
View Article and Find Full Text PDFRadiology
June 2022
From the Veneto Institute of Oncology IOV - IRCCS, via Gattamelata, 64, 35128 Padua, Italy (A.B., F.M., M.P.); Department of Information Engineering, University of Padova, Padua, Italy (A.B.); Centro di Riferimento Oncologico di Aviano (CRO) IRCCS, Aviano, Italy (M.A., G.P.); Medical Physics Unit, I
Background The translation of radiomic models into clinical practice is hindered by the limited reproducibility of features across software and studies. Standardization is needed to accelerate this process and to bring radiomics closer to clinical deployment. Purpose To assess the standardization level of seven radiomic software programs and investigate software agreement as a function of built-in image preprocessing (eg, interpolation and discretization), feature aggregation methods, and the morphological characteristics (ie, volume and shape) of the region of interest (ROI).
View Article and Find Full Text PDFJ Med Radiat Sci
December 2014
School of Health Sciences, University of Newcastle Callaghan, New South Wales, Australia.
As radiation therapy transitions from intensity modulated radiation therapy (IMRT) to volumetric modulated arc therapy (VMAT) it is important to consider the quality assurance (QA) of VMAT plans in light of what has previously been learned and developed in IMRT QA. This technical note assesses if IMRT based plan QA software, which has reduced the need in IMRT for phantom dose measurements on the linear accelerator, can be incorporated into VMAT QA processes. Twenty prostate cases were retrospectively planned using VMAT with one arc to deliver a prescription of 74 Gy in 37 fractions.
View Article and Find Full Text PDFMed Phys
July 2012
BC Cancer Agency - Abbotsford Centre, Abbotsford, BC.
Dose verification as part of plan checking is a critical component of high quality patient care. IMSure QA is a software platform used at the BC Cancer Agency that facilitates dose verification for both conformal and IMRT plans. We have recently initiated treating breast tangents using IMRT at the Fraser Valley Centre and noted increased dose discrepancies (mean difference of -3%) between Eclipse and IMSure's QA module.