Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A picosecond pump-probe resonant soft X-ray scattering measurement system has been developed at the Photon Factory storage ring for highly efficient data collection. A high-repetition-rate high-power compact laser system has been installed to improve efficiency via flexible data acquisition to a sub-MHz frequency in time-resolved experiments. Data are acquired by gating the signal of a channel electron multiplier with a pulse-counting mode capable of discriminating single-bunch soft X-ray pulses in the dark gap of the hybrid operation mode in the storage ring. The photoinduced dynamics of magnetic order for multiferroic manganite SmMnO are clearly demonstrated by the detection of transient changes in the resonant soft X-ray scattering intensity around the Mn L- and O K-edges.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9641559PMC
http://dx.doi.org/10.1107/S1600577522008724DOI Listing

Publication Analysis

Top Keywords

soft x-ray
16
resonant soft
12
x-ray scattering
12
photon factory
8
storage ring
8
x-ray
5
time-resolved resonant
4
soft
4
scattering combined
4
combined mhz
4

Similar Publications

Soft tissue sarcomas are a heterogeneous group of malignancies arising from mesenchymal cells. Recent advancements in genomic profiling have identified novel gene fusions in these tumors, offering new insights into their pathogenesis and potential therapeutic targets. Here, we describe a spindle cell sarcoma harboring a novel gene fusion.

View Article and Find Full Text PDF

Rationale: Extranodal natural killer (NK)/T-cell lymphoma is an uncommon non-Hodgkin lymphoma, prevalent in Asia. It often involves the nasal and upper airway regions but can disseminate to other sites like skin, soft tissue, testis, and gastrointestinal tract, characterized by Epstein-Barr virus association.

Patient Concerns: This report discusses a 48-year-old male initially diagnosed with Behcet syndrome with dry mouth, uveitis, pruritic macules, and human leukocyte antigen-B51 positivity.

View Article and Find Full Text PDF

Objective: To evaluate multiparametric MRI features of pediatric soft-tissue sarcomas, comparing pre-treatment and post-treatment features, and assessing correlation with clinical outcomes.

Materials And Methods: Retrospective cohort study, including pediatric patients (≤ 18 years) with histologically-confirmed soft-tissue sarcomas who underwent MRI with anatomic and functional sequences in consecutive series. Post-treatment MRI was available for a subset, and features were recorded by two readers.

View Article and Find Full Text PDF

Vacuum-compatible sub-micrometer liquid flat-jet apparatus for soft x-ray spectroscopy.

Rev Sci Instrum

September 2025

Attosecond Science Research Team, RIKEN Center for Advanced Photonics, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan.

We have developed a vacuum-compatible liquid flat-jet apparatus that delivers stable, sub-micrometer sheets for soft-x-ray spectroscopy. Interchangeable PEEKsil microjets (ϕ 25-100 μm) collide to form a leaf-like jet that runs reproducibly for more than 6 h at ∼0.1 Pa.

View Article and Find Full Text PDF

Malignant phyllodes tumors of the breast are rare fibroepithelial neoplasms with aggressive behavior and high recurrence rates. They pose significant diagnostic and therapeutic challenges due to their overlap with other malignancies, necessitating accurate diagnosis and a tailored treatment approach to improve patient outcomes. A 29-year-old Asian female initially underwent a lumpectomy for a right breast mass diagnosed as a phyllodes tumor on histopathology.

View Article and Find Full Text PDF