Temperature Changes during Implant Osteotomy Preparations in Human Cadaver Tibiae Comparing MIS Straight Drills with Densah Burs.

Genes (Basel)

Department of Periodontics and Dental Hygiene, School of Dentistry, University of Texas, Health Science Center at Houston, 7500 Cambridge St., Houston, TX 77054, USA.

Published: September 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

(1) Background: Several studies showed a sustained temperature of 47 °C or 50 °C for one minute resulted in vascular stasis and bone resorption with only limited bone regrowth over a 3-4-week healing period. The purpose of the present study was to evaluate the temperature changes (ΔΤ) that occur during the preparation of dental implant osteotomies using MIS straight drills versus Densah burs in a clockwise (cutting) drilling protocol. (2) Methods: Two hundred forty (240) osteotomies of two different systems' drills were prepared at 6 mm depth at 800, 1000, and 1200 revolutions per minute (RPM), in fresh, unembalmed tibiae, obtained by a female cadaver. ΔΤ was calculated by subtracting the baseline temperature on the tibial surface, from the maximum temperature-inside the osteotomy (ΔT = T - T). The variables were evaluated both for their individual and for their synergistic effect on ΔΤ with the use of one-, two-, three- and four-way interactions; (3) Results: An independent and a three-way interaction (drill design, drill width, and RPM) was found in all three RPM for the Densah burs and at 1000 RPM for the MIS straight drills. As Densah burs diameter increased, ΔΤ decreased. The aforementioned pattern was seen only at 1000 RPM for the MIS straight drills. The usage of drills 20 times more than the implant manufacturers' recommendation did not significantly affect the ΔΤ. A stereoscopic examination of the specimens confirmed the findings. (4) Conclusions: The independent and synergistic effect of drills' diameter, design and RPM had a significant effect on ΔΤ in human tibiae, which never exceeded the critical threshold of 47 °C.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9601368PMC
http://dx.doi.org/10.3390/genes13101716DOI Listing

Publication Analysis

Top Keywords

mis straight
16
straight drills
16
densah burs
16
temperature changes
8
drills densah
8
1000 rpm
8
rpm mis
8
drills
6
ΔΤ
6
rpm
6

Similar Publications

Aim: To compare the effect of the shape of the healing abutment, concave or straight, on the dimensions of the soft tissue after healing.

Materials And Methods: Patients needing implant therapy in the posterior area were treated with a 1-stage surgery protocol; concave (CONC) or straight (STR) healing abutments were randomly assigned after implant installation. Before surgery, a CBCT and an intra-oral scan were obtained (IOS#0); IOS#1 was taken after soft tissue healing.

View Article and Find Full Text PDF

Misperceptions of the social world can lead to actions and social policy that are detrimental to an individual's or group's well-being. Here we investigate whether misperceptions arise when participants make predictions of the modal number of ideal future sexual partners reported by heterosexual cohorts (younger cohort: 18-23 years; older cohort: 24-29 years). For both men and women and in both cohorts, the modal number of reported partners equaled 1.

View Article and Find Full Text PDF

Orthopedic surgery relies on bone drills to create tunnels for fracture fixation, bone fusion, or tendon repair. Traditional rigid and straight bone drills often pose challenges in accessing the desired entry points without risking damage to the surrounding anatomical structures, especially in minimal invasive procedures. In this study, we explore the use of hydraulic pressure waves in a flexible bone design to facilitate bone drilling.

View Article and Find Full Text PDF

The Balkans are considered a major glacial refugium where flora and fauna survived glacial periods and repopulated the rest of Europe during interglacials. While it is also thought to have harboured Pleistocene human populations, evidence linking human activity, paleoenvironmental indicators and a secure temporal placement to glacial periods is scant. Here, we present the first intra-tooth multi-isotope analysis for the European straight-tusked elephant Palaeoloxodon antiquus, on an adult male individual excavated in association with lithic artefacts at the MIS 12 site Marathousa 1 (Megalopolis basin, Greece).

View Article and Find Full Text PDF

Research on perceptions of sexual interest has documented the tendency for men to overperceive sexual interest (i.e., to perceive a social signal as indicating more sexual intent than the actor intended).

View Article and Find Full Text PDF