Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Long term follow-up of patients with esophageal atresia (EA) may be hampered by esophageal dysmotility, which affects quality of life and might lead to late complications. The endoluminal functional lumen imaging probe (EndoFlip™ Medtronic, Crospon Inc.) is an innovative diagnostic tool that assesses esophageal distensibility. Our aim was to report the use of EndoFlip™ in an EA follow-up, in order to describe distensibility patterns and to determine its possible role for functional evaluation of patients. We retrospectively collected data of EA patients, with a minimum follow-up of 9 years, who required endoscopic evaluation and underwent EndoFlip™. An adaptation of the Medtronic EF-322 protocol was applied and distensibility data were compared to those reported by Pandolfino et al. Nine patients (median age 13 years) were included in the study. The median minimum distensibility was 2.58 mm/mmHg. Signs of peristalsis were observed in three patients. In one case, the esophagogastric junction (EGJ) after Toupet fundoplication showed low distensibility. EGJ distensibility values of 2.58 mm/mmHg (median) confirmed both good esophagogastric continence and compliance. Esophagitis and absent peristalsis were found in one patient together with partial stenosis of the fundoplication, confirming the importance of surgical adaptation. Esophageal body distensibility was higher than that of the EGJ. Considering the presence of symptoms, the EndoFlip™ results seem to correlate better with the clinical picture. EndoFlip™ use was safe and feasible in children. It allowed for the measurement of esophageal distensibility and diameter and the acquisition of indirect information on motility with clinical implications. The routine use of EndoFlip™ could be part of EA follow-up, although considerable research is needed to correlate Endoflip™ system measurements to EA patient outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9600905PMC
http://dx.doi.org/10.3390/children9101426DOI Listing

Publication Analysis

Top Keywords

functional lumen
8
lumen imaging
8
imaging probe
8
esophageal atresia
8
distensibility
8
esophageal distensibility
8
endoflip™ follow-up
8
258 mm/mmhg
8
endoflip™
7
esophageal
6

Similar Publications

The timely release of chemical messengers is a crucial step in cell-to-cell communication. Does this release occur as a passive diffusion from the donor membrane or it is actively regulated? A series of studies indicated that chemical messengers' secretion is "sub-quantal". This mode of secretion demands a strongly regulated release mechanism and calls for a thorough characterization of the release sites.

View Article and Find Full Text PDF

FPR2 Agonism Attenuates Restenosis by Mitigating Neointimal Hyperplasia via ELOVL6.

FASEB J

September 2025

State Key Laboratory of Discovery and Utilization of Functional Components in Traditional Chinese Medicine, School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China.

Restenosis following endovascular intervention in lower extremity arterial disease contributes to significant morbidity and mortality. This study investigates the role of formylpeptide receptor 2 (FPR2) in neointimal hyperplasia and evaluates the therapeutic potential of the selective FPR2 agonist BMS-986235 in mitigating restenosis. FPR2 expression was significantly reduced in the popliteal and anterior tibial arteries of male amputees with restenosis compared to healthy controls.

View Article and Find Full Text PDF

Objectives: As a two-dimensional modality, venography has limitations in its capacity to measure lumen caliber and to assess stenotic disease accurately. This has implications in the management of end-stage renal-disease (ESRD) patients "no-option" candidates access for arteriovenous fistula (AVF) or graft (AVG) creation secondary to high risk of vascular access failure. The incremental diagnostic and clinical impact of intravascular ultrasound (IVUS) was quantified in this tunneled dialysis catheter dependent ESRD cohort.

View Article and Find Full Text PDF

Comparison of Anatomical and Physiological Indices of Angiographically Intermediate Left Main Coronary Artery Stenoses.

Am J Cardiol

September 2025

Faculty of Medicine, Istanbul University, Istanbul, Turkey; Department of Cardiology, Acibadem International Hospital, Istanbul, Turkey. Electronic address:

Although physiologic evaluation (e.g., fractional flow reserve) of intermediate lesions is well established in other coronary arteries, the left main coronary artery (LMCA) exhibits diagnostic challenges, hindering development of physiology-based decision-making algorithms.

View Article and Find Full Text PDF

Atrioventricular Interval Modulation: Looking Beyond Blood Pressure Needed?

JACC Clin Electrophysiol

August 2025

Department of Biomedical Engineering, CARIM Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, the Netherlands.

View Article and Find Full Text PDF