98%
921
2 minutes
20
Background: Transarterial radioembolization (TARE) is a treatment modality for liver tumors during which radioactive microspheres are injected into the hepatic arterial system. These microspheres distribute throughout the liver as a result of the blood flow until they are trapped in the arterioles because of their size. Holmium-166 ( Ho)-loaded microspheres used for TARE can be visualized and quantified with MRI, as holmium is a paramagnetic metal and locally increases the transverse relaxation rate . The current Ho quantification method does not take regional differences in baseline values (such as between tumors and healthy tissue) into account, which intrinsically results in a systematic error in the estimated absorbed dose distribution. As this estimated absorbed dose distribution can be used to predict response to treatment of tumors and potential toxicity in healthy tissue, a high accuracy of absorbed dose estimation is required.
Purpose: To evaluate pre-existing differences in distributions between tumor tissue and healthy tissue and assess the feasibility and accuracy of voxelwise subtraction-based calculation for MRI-based dosimetry of holmium-166 transarterial radioembolization ( Ho TARE).
Methods: MRI data obtained in six patients who underwent Ho TARE of the liver as part of a clinical study was retrospectively evaluated. Pretreatment differences in distributions between tumor tissue and healthy tissue were characterized. Same-day pre- and post-treatment maps were aligned using a deformable registration algorithm and subsequently subtracted to generate voxelwise maps and resultant absorbed dose maps. Image registration accuracy was quantified using the dice similarity coefficient (DSC), relative overlay (RO), and surface dice (≤4 mm; SDSC). Voxelwise subtraction-based absorbed dose maps were quantitatively (root-mean-square error, RMSE) and visually compared to the current MRI-based mean subtraction method and routinely used SPECT-based dosimetry.
Results: Pretreatment values were lower in tumors than in healthy liver tissue (mean 36.8 s vs. 55.7 s , P = 0.004). Image registration improved the mean DSC of 0.83 (range: 0.70-0.88) to 0.95 (range: 0.92-0.97), mean RO of 0.71 (range 0.53-0.78) to 0.90 (range: 0.86-0.94), and mean SDSC ≤4 mm of 0.47 (range: 0.28-0.67) to 0.97 (range: 0.96-0.98). Voxelwise subtraction-based absorbed dose maps yielded a higher tumor-absorbed dose (median increase of 9.0%) and lower healthy liver-absorbed dose (median decrease of 13.8%) compared to the mean subtraction method. Voxelwise subtraction-based absorbed dose maps corresponded better to SPECT-based absorbed dose maps, reflected by a lower RMSE in three of six patients.
Conclusions: Voxelwise subtraction presents a robust alternative method for MRI-based dosimetry of Ho microspheres that accounts for pre-existing differences, and appears to correspond better with SPECT-based dosimetry compared to the currently implemented mean subtraction method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mp.16014 | DOI Listing |
Cardiovasc Intervent Radiol
September 2025
Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Background: To evaluate predictors of outcomes in colorectal liver metastases (CLM) patients undergoing 90Y radioembolization (TARE), focusing on the impact of tumor absorbed dose.
Materials And Methods: Patients' characteristics and dosimetry assessments were analyzed in 231 patients undergoing 329 TARE sessions from 09/2009 to 07/2023. Response was assessed using RECIST1.
Radiat Environ Biophys
September 2025
Environmental Physics Department, Institute for Energy Security and Environmental Safety, HUN-REN Centre for Energy Research, Budapest, Hungary.
Variability in radiation-related health risk and genetic susceptibility to radiation effects within a population is a key issue for radiation protection. Besides differences in the health and biological effects of the same radiation dose, individual variability may also affect dose distribution and its consequences for the same exposure. As exposure to radon progeny affects a large population and has a well-established dose-effect relationship, investigating individual variability upon radon exposure may be particularly important.
View Article and Find Full Text PDFEnviron Res
September 2025
College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, Chengdu 610059, Sichuan,P.R.China; Applied Nuclear Technology in Geosciences Key Laboratory of Sichuan Province, Chengdu University of Technology, Chengdu 610059, P.R.China.
Naturally occurring radioactive materials (NORM) are present in waste generated during shale gas drilling activities and pose potential risks to the environment, drawing increasing public and scientific attention. In this study, soil, wastewater and effluent samples were collected across multiple operational stages of shale gas development in Southwest China. A combination of in-situ gamma absorbed dose rate in air, soil radon concentration, radionuclide activity concentrations, and conventional hazard indices was used to evaluate environmental radioactivity and potential occupational exposure.
View Article and Find Full Text PDFPhotodiagnosis Photodyn Ther
September 2025
Institute of Medical Engineering and Mechatronics, Ulm University of Applied Sciences, Albert-Einstein-Allee 55, 89081 Ulm, Germany.
Bacterial inflammatory skin conditions, especially those caused by Cutibacterium acnes (C. acnes), are among the most common skin diseases globally. While C.
View Article and Find Full Text PDFTurk J Pharm Sci
September 2025
University of Maryland, Department of Pharmaceutical Sciences, Baltimore, USA.
Objectives: Norvir oral powder [ritonavir (RTV)] employs polyvinylpyrrolidone/vinyl acetate as the polymer to formulate an amorphous solid dispersion. Its oral absolute bioavailability is 70% in the fasted state, and it has negative food effects. The aim of this study was to perform in vitro dissolution of Norvir powder and Wagner-Nelson deconvolution of data under fasted, moderate fat, and high fat conditions in order to elucidate the relevance of dissolution testing.
View Article and Find Full Text PDF