Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Aeromonas salmonicida is the pathogen underlying furunculosis, causing a septicemic infection that influences both salmonid and non-salmonid fish. Early diagnosis of these contagions is essential for disease surveillance and prevention, so a rapid and sensitive approach is needed. Herein, a recombinase polymerase amplification EXO (RPA-EXO) assay and RPA with a lateral flow dipstick (RPA-LFD) were produced for testing A. salmonicida. The RPA-EXO and RPA-LFD primer sets were devised based on the conserved fragment sequence of the vapA gene. Then, RPA-EXO and RPA-LFD reaction systems were established, and the reaction temperature and time were optimized. After optimization, the RPA-EXO method was capable of testing A. salmonicida within 10 min, and the RPA-LFD method could detect A. salmonicida in only 5 min. The RPA-EXO and RPA-LFD methods exhibited high specificity with no cross-reaction with other strains. To assess sensitivity, a partial vapA gene was cloned, and serial plasmid dilutions were created ranging from 1 × 10 to 1 × 10 copies/μL. The detection limit of RPA-EXO was 1 × 10 copies/μL, and the detection limit of RPA-LFD was 1 copy/μL. For spiked turbot tissue samples, the sensitivity detection of A. salmonicida was 1.2 × 10 CFU/mL and 1.2 CFU/mL by RPA-EXO and RPA-LFD, respectively. In comparative analyses of clinical samples, the diagnostic results of RPA-EXO and RPA-LFD were compared with those of the standard conventional PCR test and showed nearly 100% consistency. Therefore, our RPA-EXO and RPA-LFD assays exhibited excellent specificity and sensitivity, which provided two simple, fast and dependable methods to conduct large-scale field investigations of A. salmonicida in resource-limited settings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10126-022-10170-8 | DOI Listing |