A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

In Vivo Repeatability and Multiscanner Reproducibility of MRI Radiomics Features in Patients With Monoclonal Plasma Cell Disorders: A Prospective Bi-institutional Study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: Despite the extensive number of publications in the field of radiomics, radiomics algorithms barely enter large-scale clinical application. Supposedly, the low external generalizability of radiomics models is one of the main reasons, which hinders the translation from research to clinical application. The objectives of this study were to investigate reproducibility of radiomics features (RFs) in vivo under variation of patient positioning, magnetic resonance imaging (MRI) sequence, and MRI scanners, and to identify a subgroup of RFs that shows acceptable reproducibility across all different acquisition scenarios.

Materials And Methods: Between November 30, 2020 and February 16, 2021, 55 patients with monoclonal plasma cell disorders were included in this prospective, bi-institutional, single-vendor study. Participants underwent one reference scan at a 1.5 T MRI scanner and several retest scans: once after simple repositioning, once with a second MRI protocol, once at another 1.5 T scanner, and once at a 3 T scanner. Radiomics feature from the bone marrow of the left hip bone were extracted, both from original scans and after different image normalizations. Intraclass correlation coefficient (ICC) was used to assess RF repeatability and reproducibility.

Results: Fifty-five participants (mean age, 59 ± 7 years; 36 men) were enrolled. For T1-weighted images after muscle normalization, in the simple test-retest experiment, 110 (37%) of 295 RFs showed an ICC ≥0.8: 54 (61%) of 89 first-order features (FOFs), 35 (95%) of 37 volume and shape features, and 21 (12%) of 169 texture features (TFs). When the retest was performed with different technical settings, even after muscle normalization, the number of FOF/TF with an ICC ≥0.8 declined to 58/13 for the second protocol, 29/7 for the second 1.5 T scanner, and 49/7 for the 3 T scanner, respectively. Twenty-five (28%) of the 89 FOFs and 6 (4%) of the 169 TFs from muscle-normalized T1-weighted images showed an ICC ≥0.8 throughout all repeatability and reproducibility experiments.

Conclusions: In vivo, only few RFs are reproducible with different MRI sequences or different MRI scanners, even after application of a simple image normalization. Radiomics features selected by a repeatability experiment only are not necessarily suited to build radiomics models for multicenter clinical application. This study isolated a subset of RFs, which are robust to variations in MRI acquisition observed in scanners from 1 vendor, and therefore are candidates to build reproducible radiomics models for monoclonal plasma cell disorders for multicentric applications, at least when centers are equipped with scanners from this vendor.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLI.0000000000000927DOI Listing

Publication Analysis

Top Keywords

radiomics features
12
monoclonal plasma
12
plasma cell
12
cell disorders
12
clinical application
12
radiomics models
12
icc ≥08
12
radiomics
9
mri
8
patients monoclonal
8

Similar Publications