A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A Single-Center Prospective Study of the Effects of Different Methods of Phlebotomy in the Emergency Department on Blood Sample Hemolysis Rates. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Hemolysis is more commonly seen in the emergency department and causes delays in diagnosis, hospitalization, discharge, and treatment of patients. The aim of this study was to determine the most appropriate phlebotomy method and device to reduce blood sample hemolysis in the emergency department.

Methods: This prospective, comparative descriptive study involved patients who presented to the emergency department with any medical condition and required blood sampling. Patients were divided into 6 groups according to the method of phlebotomy and the device used for phlebotomy. Data were analyzed with logistic regression.

Results: A total of 715 patients participated in the study. The blood sample hemolysis rate in the emergency department was 25.7%. When the hemolysis rates were compared with a steel straight needle or intravenous catheter, it was found that the use of steel straight needle significantly reduced hemolysis. Blood drawing through a 20 G intravenous catheter with Luer-Lock access device reduces the risk of hemolysis. Male sex and difficult blood collection also have been shown to increase the risk of hemolysis.

Discussion: Blood should be drawn with a steel straight needle instead of an intravenous catheter. However, when that is not possible, we recommend the use of a 20 G intravenous catheter with Luer-Lock access device if a blood sample is to be drawn from intravenous line.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jen.2022.08.005DOI Listing

Publication Analysis

Top Keywords

emergency department
16
blood sample
16
intravenous catheter
16
sample hemolysis
12
steel straight
12
straight needle
12
blood
8
hemolysis rates
8
needle intravenous
8
20 g intravenous
8

Similar Publications