A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A-phase index: an alternative view for sleep stability analysis based on automatic detection of the A-phases from the cyclic alternating pattern. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Study Objectives: Sleep stability can be studied by evaluating the cyclic alternating pattern (CAP) in electroencephalogram (EEG) signals. The present study presents a novel approach for assessing sleep stability, developing an index based on the CAP A-phase characteristics to display a sleep stability profile for a whole night's sleep.

Methods: Two ensemble classifiers were developed to automatically score the signals, one for "A-phase" and the other for "non-rapid eye movement" estimation. Both were based on three one-dimension convolutional neural networks. Six different inputs were produced from the EEG signal to feed the ensembles' classifiers. A proposed heuristic-oriented search algorithm individually tuned the classifiers' structures. The outputs of the two ensembles were combined to estimate the A-phase index (API). The models can also assess the A-phase subtypes, their API, and the CAP cycles and rate.

Results: Four dataset variations were considered, examining healthy and sleep-disordered subjects. The A-phase average estimation's accuracy, sensitivity, and specificity range was 82%-87%, 72%-80%, and 82%-88%, respectively. A similar performance was attained for the A-phase subtype's assessments, with an accuracy range of 82%-88%. Furthermore, in the examined dataset's variations, the API metric's average error varied from 0.15 to 0.25 (with a median range of 0.11-0.24). These results were attained without manually removing wake or rapid eye movement periods, leading to a methodology suitable to produce a fully automatic CAP scoring algorithm.

Conclusions: Metrics based on API can be understood as a new view for CAP analysis, where the goal is to produce and examine a sleep stability profile.

Download full-text PDF

Source
http://dx.doi.org/10.1093/sleep/zsac217DOI Listing

Publication Analysis

Top Keywords

sleep stability
20
cyclic alternating
8
alternating pattern
8
stability profile
8
a-phase
6
sleep
5
stability
5
cap
5
a-phase alternative
4
alternative view
4

Similar Publications