A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A roller scanning type prostate palpation sensor system using a cantilever beam type force measurement. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Palpation has been used for centuries in medicine as a screening and diagnosis modality for a number of pathological conditions. However, this technique is subjective since palpation sensitivity depends on the skill and experience of a medical examiner. An objective approach to acquire quantitative tactile information is needed. A roller scanning type palpation sensor system consisting of an x-axis linear slider and a palpation probe for detecting lumps in a soft object such as the prostate tissue is proposed and fabricated in this study. By translating the slider and changing the palpation angle of the probe, a chrome steel ball which was the contact component indented and scanned the surface of soft silicone phantoms embedded with hard lumps. Lumps were detected by measuring reaction force waveform fluctuations. Fundamental characteristics of the proposed sensor system were validated by comparison with the ground truth load cell output and showed a strong linear correlation with r=0.9985. On silicone samples with hard lumps, the system was able to detect lumps of various sizes embedded at the depth of 5mm. From the results, the proposed sensor system holds potential for tissue characterization.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC48229.2022.9870835DOI Listing

Publication Analysis

Top Keywords

sensor system
16
roller scanning
8
scanning type
8
palpation sensor
8
hard lumps
8
proposed sensor
8
palpation
6
system
5
lumps
5
type prostate
4