A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Modified Clavien-Dindo-Sink system is reliable for classifying complications following surgical treatment of early-onset scoliosis. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Appropriately measuring and classifying surgical complications is a critical component of research in vulnerable populations, including children with early-onset scoliosis (EOS). The purpose of this study was to assess the inter- and intra-rater reliability of a modified Clavien-Dindo-Sink system (CDS) classification system for EOS patients among a group of pediatric spinal deformity surgeons.

Methods: Thirty case scenarios were developed and presented to experienced surgeons in an international spine study group. For each case, surgeons were asked to select a level of severity based on the modified CDS system to assess inter-rater reliability. The survey was administered on two occasions to allow for assessment of intra-rater reliability. Weighted Kappa values were calculated, with 0.61 to 0.80 considered substantial agreement and 0.81 to 1.00 considered nearly perfect agreement.

Results: 11/12 (91.7%) surgeons completed the first-round survey and 8/12 (66.7%) completed the second. Inter-observer weighted kappa values for the first and second survey were 0.75 [95% CI 0.56-0.94], indicating substantial agreement, and 0.84 [95% CI 0.70-0.98], indicating nearly perfect agreement, respectively. Intra-observer reliability was 0.86 (range 0.74-0.95) between the first and second surveys, indicating nearly perfect agreement .

Conclusion: The modified CDS classification system demonstrated substantial to nearly perfect agreement between and within observers for the evaluation of complications following the surgical treatment of EOS patients. Adoption of this reliable classification system as a standard for reporting complications in EOS patients can be a valuable tool for future research endeavors, as we seek to ultimately improve surgical practices and patient outcomes.

Level Of Evidence: Level V.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s43390-022-00573-xDOI Listing

Publication Analysis

Top Keywords

classification system
12
eos patients
12
perfect agreement
12
modified clavien-dindo-sink
8
clavien-dindo-sink system
8
complications surgical
8
surgical treatment
8
early-onset scoliosis
8
intra-rater reliability
8
cds classification
8

Similar Publications