Background: BK virus nephropathy (BKVN) is a frequent and serious post-transplant complication and undermines realization of the full benefits of kidney transplantation. We developed a Bak amplicon-based standard curve for absolute quantification of BKV VP1 mRNA copy number in the real time quantitative PCR (RT-qPCR) assay and investigated the performance characteristics of this novel assay.
Methods: We determined analytical specificity, sensitivity, and precision of our 73 bp mouse Bak amplicon based standard curve for absolute quantification of BKV VP1 mRNA in RT-qPCR assays. The diagnostic accuracy of the Bak standard curve in the RT-qPCR assay for the noninvasive diagnosis of BKVN in human kidney allograft recipients was investigated by quantification of BKV VP1 mRNA copy number in 192 urine samples matched to 192 kidney allograft biopsies from 155 unique kidney allograft recipients. Intraclass correlation coefficients (ICC) were calculated for the threshold cycles (Ct) and BKV VP1 mRNA copy number observed in the RT-qPCR assay with the Bak standard curve or the BKV standard curve.
Results: Performance characteristics of the Bak amplicon-based RT-qPCR assay were exceptional with a slope of -3.291, Y-intercept of 38.60, R value of 1.00, efficiency of 101% and error of 0.014. Amplification was specific for the Bak amplicon. Intra assay standard deviation (SD) was 0.08 or less and inter assay SD was 0.11 or less for 31 cycles or less of amplification of the Bak amplicon. Receiver operating characteristic (ROC) curve analysis of BKV VP1 mRNA copy number in 192 biopsy matched urines yielded an area under the ROC of 0.982 (95% CI, 0.964 to 0.999, P < 0.0001) for discriminating patients with BKVN biopsies from patients without BKVN biopsies. The striking identity in the measurement of BKV VP1 mRNA copy numbers in the Bak amplicon-based RT-qPCR assay and in the BKV amplicon-based RT-qPCR assay was shown by an ICC of 1.00 when the Cts were compared, and an ICC of 0.99 when the log BKV VP1 mRNA copy numbers were compared.
Conclusions: Bak standard curve for absolute quantification of BKV VP1 mRNA copy number in the RT-qPCR assay demonstrated high efficiency, short and long-term precision and analytical specificity. BKVN was diagnosed with high accuracy. Our new findings, viewed in the light of our earlier demonstration that absolute quantification of a panel of mRNAs encoding immunoregulatory proteins is feasible with the Bak amplicon-based RT-qPCR assays, suggest that the Bak standard curve could serve as a universal calibrator for absolute quantification of transcripts in RT-qPCR assays and help reduce the workload, costs and eliminate contamination of genes of interest by repeated amplification of gene specific standard curves.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jim.2022.113341 | DOI Listing |
JAMA Cardiol
September 2025
Department of Cardiology, Inselspital University Hospital of Bern, University of Bern, Bern, Switzerland.
Importance: Right anomalous aortic origin of a coronary artery (R-AAOCA) is a rare congenital condition increasingly diagnosed with the growing use of cardiac imaging. Due to dynamic compression of the anomalous vessel, invasive fractional flow reserve (FFR) during a dobutamine-atropine volume challenge (FFR-dobutamine) is considered the reference standard. A reliable alternative method is needed to reduce extensive invasive testing, but it remains uncertain whether noninvasive imaging can accurately assess the hemodynamic relevance of R-AAOCA.
View Article and Find Full Text PDFEur Radiol Exp
September 2025
Department of Radio-diagnosis, Faculty of Human Medicine, Zagazig University, Zagazig, Egypt.
Background: Bone marrow (BM) lesion differentiation remains challenging, and quantitative magnetic resonance imaging (MRI) may enhance accuracy over conventional methods. We evaluated the diagnostic value and inter-reader reliability of Dixon-based signal drop (%drop) and fat fraction percentage (%fat) as adjuncts to existing protocols.
Materials And Methods: In this prospective two-center study, 172 patients with BM signal abnormalities underwent standardized 1.
Graefes Arch Clin Exp Ophthalmol
September 2025
Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College Hospital, No. 1 Shuaifuyuan Wangfujing Dongcheng District, China, 100730, Beijing.
Purpose: To evaluate the predictive value of the preoperative orientation and offset of angle alpha(chord alpha) and angle kappa(chord mu) for visual outcomes in patients who underwent trifocal intraocular lens (IOL) implantation.
Methods: Patient records of eyes that underwent AT LISA tri 839MP implantation were retrospectively collected and grouped according to the preoperative offset and orientations of chord alpha and chord mu. The two-dimensional location of each angle was described by the interaction of the orientation and offset.
Pediatr Crit Care Med
September 2025
Waisman Brain Imaging Laboratory, University of Wisconsin, Madison, WI.
Objectives: Elevated intracranial pressure (ICP) is a complication of severe traumatic brain injury (TBI) that carries a risk of secondary brain injury. This study investigated the association between ICP burden and brain injury patterns on MRI in children with severe TBI.
Design, Setting, And Patients: Secondary analysis of the Approaches and Decisions in Acute Pediatric TBI (ADAPT) study, which included children with severe TBI (Glasgow Coma Scale score < 9) who received a clinical MRI within 30 days of injury.
J Clin Lab Anal
September 2025
Department of Nursing, National Tainan Junior College of Nursing, Tainan, Taiwan.
Background: Improving efficiency and reducing turnaround time are crucial in clinical laboratories. While automated analyzers such as the Beckman Coulter DxH 900 streamline workflow, subtle abnormalities like blasts and immature granulocytes (IGs) may be missed, especially in the absence of WBC-related suspect messages. This study evaluated whether integrating cell population data (CPD) with instrument messages could enhance detection accuracy.
View Article and Find Full Text PDF