Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: This study evaluated how extended match time (90 + 30 min) affected physiological responses and fatigue in male soccer players.

Methods: Twenty competitive players (mean ± SD: age, 20 ± 1 yr; maximal oxygen uptake, 59 ± 4 mL·min -1 ·kg -1 ) completed an experimental match with their activity pattern and heart rate assessed throughout the game, whereas countermovement jump performance and repeated sprint ability were tested and quadriceps muscle biopsies and venous blood samples were taken at baseline and after 90 and 120 min of match play.

Results: Less high-intensity running (12%) was performed in extra time in association with fewer intense accelerations and decelerations per minute compared with normal time. Peak sprint speed was 11% lower in extra time compared with normal time, and fatigue also manifested in impaired postmatch repeated sprint ability and countermovement jump performance (all P < 0.05). Muscle glycogen declined from 373 ± 59 mmol·kg -1 dry weight (dw) at baseline to 266 ± 64 mmol·kg -1 dw after 90 min, with a further decline to 186 ± 56 mmol·kg -1 dw after extra time ( P < 0.05) and with single-fiber analyses revealing depleted or very low glycogen levels in ~75% of both slow and fast twitch fibers. Blood glucose did not change during the first 90-min but declined ( P < 0.05) to 81 ± 8 mg·dL -1 after extra time. Plasma glycerol and ammonia peaked at 236 ± 33 mg·dL -1 and 75 ± 21 μmol·L -1 after the extra period.

Conclusions: These findings demonstrate exacerbated fatigue after extra time compared with normal time, which seems to be associated with muscle glycogen depletion, reductions in blood glucose levels, and hyperammonemia. Together, this points to metabolic disturbances being a major part of the integrated and multifaceted fatigue response during extended soccer match play.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9770137PMC
http://dx.doi.org/10.1249/MSS.0000000000003021DOI Listing

Publication Analysis

Top Keywords

extra time
20
compared normal
12
normal time
12
time
10
extended match
8
match time
8
physiological responses
8
male soccer
8
countermovement jump
8
jump performance
8

Similar Publications

Background: Nurses remain critical in newborn care delivery in Kenya. However, persistent nurse shortages in newborn units limit their ability to provide optimal care. Staff shortages contribute to missed care and high workloads, negatively impacting the motivation and well-being of nurses.

View Article and Find Full Text PDF

Nontargeted Screening of Fingermark Residue Using Comprehensive Two-Dimensional Gas Chromatography-Time-of-Flight Mass Spectrometry for Future Use in Forensic Applications.

J Am Soc Mass Spectrom

September 2025

Nontargeted Separations Laboratory, Chemistry Department, William & Mary, Integrated Science Center 1053, 540 Landrum Drive, Williamsburg, Virginia 23188, United States.

Fingerprints are routinely used as evidence in forensic investigations. Fingermarks, any mark left by a donor whether a complete print or not, include sweat and oil excreted by the donor. The chemical components of fingermarks are typically analyzed by gas chromatography-mass spectrometry (GC-MS).

View Article and Find Full Text PDF

Background: Pilon fractures refer to distal tibial fractures that may involve extra-articular, partial articular, or complete intra-articular components, most commonly caused by high-energy trauma. The choice between early (<72 hours) and delayed (>7 days) surgical fixation significantly impacts clinical outcomes. This study aimed to compare the effects of early vs.

View Article and Find Full Text PDF

Introduction: Absence of language development is a condition encountered across a large range of neurodevelopmental disorders, including a significant proportion of children with autism spectrum disorder. The neurobiological underpinnings of non-verbal ASD (nvASD) remain poorly understood.

Methods: This study employed multimodal MRI to investigate white matter (WM) microstructural abnormalities in nvASD, focusing on language-related pathways.

View Article and Find Full Text PDF

Chemically and Electromagnetically dual-enhanced COFs-Au@AgNPs SERS sensor integrated with deep learning for ultrasensitive detection of neonicotinoid pesticides.

Anal Chim Acta

November 2025

Measurement Technology & Instrumentation Key Laboratory of Hebei Province, Institute of Electrical Engineering, Yanshan University, Qinhuangdao, 066004, China.

Background: With the development of modern agriculture, neonicotinoid pesticides have been widely used due to their high efficiency and strong systemic properties. However, excessive use leads to the accumulation of residues in the food chain, threatening the ecosystem and human health. Pesticide residues are easily accumulated in oilseed crops and become concentrated during the edible oil refining process.

View Article and Find Full Text PDF