Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
A sustainable downscaled procedure using smartphone-based colorimetric determination of manganese (Mn(II)) was developed. This novel Mn(II) determination procedure is proposed using a simple, available microwell-plate platform and a smartphone as a detector. This approach is based on the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by periodate using Mn(II) as a catalyst. The catalytic kinetics of Mn(II) under different conditions was investigated to determine the optimum condition where the different catalytic activities of various concentrations of Mn(II) evince. Under the optimum condition, the bluish-green product of oxidized TMB, proportioned to the concentration of Mn(II), was monitored using a smartphone camera, and the color signals were processed using ImageJ Software. The developed procedure showed great selectivity and sensitivity as linearity ranged from 1.8 × 10 to 4.6 × 10 M (0.1 to 2.5 μg/mL). The limits of detection and quantitation were 3.6 × 10 and 1.1 × 10 M (0.2 and 0.6 μg/mL), respectively. The determination of Mn(II) in freshwater samples was demonstrated to assess environmental water quality as an initial model to more easily promote water management according to the United Nations Sustainable Development Goals (UN-SDGs). The intensity of the red could be successfully applied to evaluate Mn(II) in canals and river water with no significant differences compared with the reference method of Inductively Coupled Plasma Optical Emission Spectrometry at a confidence level of 95%.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9369721 | PMC |
http://dx.doi.org/10.3390/molecules27154841 | DOI Listing |