Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Percutaneous epiphysiodesis using transphyseal screws (PETS) is a common procedure to correct lower extremity limb-length discrepancies in the pediatric population. A potential complication of this procedure is development of tibial valgus deformity, which may occur secondary to decreased screw purchase in the thinner medial proximal tibial epiphysis. The thickness of the proximal tibial epiphysis has not yet been well quantified, which was the aim of this study.

Methods: Three-dimensional surface scans of 32 cadaveric proximal tibial epiphyses in specimens aged 3 to 17 years old were obtained and computer modeling software was utilized to measure the thickness of the proximal tibial epiphysis at 20 standardized potential screw insertion points according to a generated 5×4 map.

Results: When normalized to the total width of the proximal tibial epiphysis, the lateral side is thicker compared with the medial side. The positions with the greatest thickness are located at the midline in the sagittal plane and 33% of the total physeal width away from the medial and lateral edges in the coronal plane (0.265 and 0.261 normalized thickness, respectively). The proximal tibial epiphysis is particularly thin 25% from the medial edge (normalized thickness range: 0.196 to 0.221). Multiple regression analysis revealed a significant relationship between increasing age and female sex with thinner normalized medial and lateral heights.

Conclusions: During PETS, areas for greater screw purchase are located centrally in the sagittal plane and 33% of the total width away from the medial and lateral edges of the proximal tibial epiphysis in the coronal plane. Caution should be taken when inserting screws in the medial 25% of the proximal tibial epiphysis as it is thinner relative to the lateral edge, particularly in females.

Clinical Relevance: This study provides quantitative, anatomic data on the thickness of the proximal tibial epiphysis, which can direct screw placement during PETS for correcting limb-length discrepancies. These data may help lessen the risk of developing tibial valgus deformity although future clinical studies are necessary to fully evaluate this possibility.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BPO.0000000000002231DOI Listing

Publication Analysis

Top Keywords

proximal tibial
40
tibial epiphysis
36
thickness proximal
16
tibial
12
medial lateral
12
proximal
10
epiphysis
9
percutaneous epiphysiodesis
8
epiphysiodesis transphyseal
8
transphyseal screws
8

Similar Publications

Atypical proximal tibial fractures in adolescents are rare, particularly when linked to hormonal therapy for short stature. This case series reports the clinical and imaging features of atypical proximal tibial and distal femoral physeal fractures in male adolescents undergoing combined growth hormone (GH) and aromatase inhibitor (AI) therapy for idiopathic short stature. We report three cases of skeletally immature male adolescents (ages 12-16) treated with GH and anastrozole who presented with acute leg pain following low-energy trauma during soccer.

View Article and Find Full Text PDF

Tibia-Fibula Relative Motion During Gait Cycle by 2D-3D Registration.

J Orthop Res

September 2025

Department of Orthopedic Surgery, Beijing Chaoyang Hospital, Capital Medical University, Beijing, Chaoyang District, China.

Injuries to the distal tibiofibular joint are often associated with ankle fractures, sports-related injuries, or instability, whereas proximal tibiofibular joint injuries are more commonly present with lateral- or posterolateral-compartment lesions of the knee. These conditions may be related to the relative motion between the tibia and fibula; however, precise movement patterns have yet to be fully elucidated. This study analyzes the relative motion of the tibia and fibula in 16 healthy adults (32 bones; 8 males and 8 females) throughout a normal gait cycle.

View Article and Find Full Text PDF

Introduction/background: Complex articular fractures around the knee in the elderly patient present an ongoing challenge regarding optimal treatment. While extensive research has evaluated immediate arthroplasty following fracture of the proximal femur, distal femur, proximal humerus, and elbow, relatively little focus has been given to immediate arthroplasty following complex tibia plateau fractures.

Methods: As seen with many other fractures, arthroplasty can shorten recovery and hospital stay and allow early weight-bearing with improved mobility while minimizing complications and possible future conversion arthroplasty cost.

View Article and Find Full Text PDF

Giant cell tumor (GCT) of the bone, although benign, demonstrates local aggressiveness, a potential for recurrence, and, in rare instances, malignant transformation. Functional preservation is crucial in cases involving the articular surface, often utilizing the Sandwich Technique. We propose an enhanced reconstruction method using the inner table of the iliac crest in a reverse fashion, offering a more anatomically contoured proximal tibial plateau and reducing donor site morbidity compared to tricortical iliac crest grafting.

View Article and Find Full Text PDF

The use of cementless total knee arthroplasty (TKA) has significantly increased over the past decade. However, there is no objective criteria or consensus on parameters for patient selection for cementless TKA. The purpose of this study was to develop a machine learning model based on patient and radiographic parameters that could identify patients indicated for cementless TKA.

View Article and Find Full Text PDF