A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Ultrasound-based computer-aided diagnosis for cytologically indeterminate thyroid nodules with different radiologists. | LitMetric

Ultrasound-based computer-aided diagnosis for cytologically indeterminate thyroid nodules with different radiologists.

Clin Hemorheol Microcirc

Department of Ultrasound, Zhongshan Hospital, Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, China.

Published: December 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To evaluate a computer-aided diagnosis (CAD) technique in predicting malignancy for cytologically indeterminate thyroid nodules (TNs) as compared with different experienced radiologists.

Method: 436 patients with 436 cytologically indeterminate TNs on fine-needle aspiration cytology (FNAC) were included and all were confirmed by surgical pathology. They were retrospectively analyzed with respect to ultrasound (US) characteristics using a commercially available CAD system (AmCAD-UT; AmCad BioMed, Taiwan, China) and reviewed by one junior and one senior radiologists.The CAD system and different experienced radiologists stratified the risk of malignancy using ACR TI-RADS category. The diagnostic performance by different experienced radiologists independently and after consulting the CAD (different experienced radiologists + CAD) and by the CAD alone were compared.

Results: The different experienced radiologists showed significantly higher specificities than the CAD system alone. The combination of radiologist and CAD system showed improved diagnostic performance with an AUC (Area under the curve) of 0.740 in the senior radiologist and 0.677 in the junior radiologist, as compared with CAD (AUC: 0.585) alone (all P < 0.05). The combination of senior radiologist and CAD system had the highest diagnostic performance (AUC: 0.740) and specificity (68.9%) compared to the others (all P < 0.05).

Conclusion: The CAD system may play the potential role as a decision-making assistant alongside radiologists for differential diagnosis of TNs with indeterminate cytology.

Download full-text PDF

Source
http://dx.doi.org/10.3233/CH-221423DOI Listing

Publication Analysis

Top Keywords

cad system
16
cytologically indeterminate
12
experienced radiologists
12
computer-aided diagnosis
8
indeterminate thyroid
8
thyroid nodules
8
cad
8
diagnostic performance
8
experienced
5
ultrasound-based computer-aided
4

Similar Publications