Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9271146PMC
http://dx.doi.org/10.1186/s13568-022-01427-5DOI Listing

Publication Analysis

Top Keywords

correction alternative
4
alternative phage
4
phage display
4
display phage
4
phage m13
4
m13 remain
4
remain viable
4
viable intestines
4
intestines poultry
4
poultry causing
4

Similar Publications

Accurate detection of tandem repeats exposes ubiquitous reuse of biological sequences.

Nucleic Acids Res

September 2025

Department of Biomedical Informatics, University of Pittsburgh, Pittsburgh, PA 15206, United States.

Tandem repetition is one of the major processes underlying genome evolution and phenotypic diversification. While newly formed tandem repeats are often easy to identify, it is more challenging to detect repeat copies as they diverge over evolutionary timescales. Existing programs for finding tandem repeats return markedly different results, and it is unclear which predictions are more correct and how much room remains for improvement.

View Article and Find Full Text PDF

Purpose: To present a case of synthetic intrastromal corneal ring segment (ICRS) intrusion secondary to necrosis and migration, managed by implantation of corneal allogenic intrastromal ring segments (CAIRS) within the preexisting tunnel.

Methods: A 24-year-old man with known keratoconus underwent bilateral ICRS implantation. He presented with blurred vision in the right eye 6 weeks after the procedure.

View Article and Find Full Text PDF

Measurement appropriateness concerns the question of whether the test or survey scale under consideration can provide a valid measure for a specific individual. An aberrant item response pattern would provide internal counterevidence against using the test/scale for this person, whereas a more typical item response pattern would imply a fit of the measure to the person. Traditional approaches, including the popular Lz person fit statistic, are hampered by their two-stage estimation procedure and the fact that the fit for the person is determined based on the model calibrated on data that include the misfitting persons.

View Article and Find Full Text PDF

Background: South Africa faces emerging resistance to TB drugs like bedaquiline. Phenotypic drug susceptibility testing (DST), the current reference standard for bedaquiline DST, has long turnaround times. Targeted next-generation sequencing (tNGS) offers a comprehensive alternative, potentially delivering faster results.

View Article and Find Full Text PDF

Purpose: This study aimed to compare the dimensional and positional deviations of additively manufactured removable dies fabricated using two bio-based resins and one conventional dental cast resin, while also evaluating these outcomes over a 4-week period.

Materials And Methods: A right mandibular first molar preparation on a typodont was scanned to digitally design removable dies and hollow partial arch casts. Based on a priori power analysis, a total of 30 dies (n = 10) and three hollow casts (n = 1) were fabricated using additive manufacturing (AM) from three different dental cast resins: DentaMODEL (DM), FotoDent bio-based model (CB), and soy-based resin (SB).

View Article and Find Full Text PDF