Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Particle counting analysis (PCA) with a multi-stage scintillation detector shows a new perspective on angularly resolved spectral characterization of GeV-scale, multi-species ion beams produced by high-power lasers. The diagnosis provides a mass-dependent ion energy spectrum based on time-of-flight and pulse-height analysis of single particle events detected through repetitive experiments. With a novel arrangement of multiple scintillators with different ions stopping powers, PCA offers potential advantages over commonly used diagnostic instruments (CR-39, radiochromic films, Thomson parabola, etc.) in terms of coverage solid angle, detection efficiency for GeV-ions, and real-time analysis during the experiment. The basic detector unit was tested using 230-MeV proton beam from a synchrotron facility, where we demonstrated its potential ability to discriminate major ion species accelerated in laser-plasma experiments (i.e., protons, deuterons, carbon, and oxygen ions) with excellent energy and mass resolution. The proposed diagnostic concept would be essential for a better understanding of laser-driven particle acceleration, which paves the way toward all-optical compact accelerators for a range of applications.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0078817DOI Listing

Publication Analysis

Top Keywords

multi-stage scintillation
8
gev-scale multi-species
8
multi-species ion
8
laser-driven particle
8
particle acceleration
8
scintillation counter
4
counter gev-scale
4
ion
4
ion spectroscopy
4
spectroscopy laser-driven
4

Similar Publications

Particle counting analysis (PCA) with a multi-stage scintillation detector shows a new perspective on angularly resolved spectral characterization of GeV-scale, multi-species ion beams produced by high-power lasers. The diagnosis provides a mass-dependent ion energy spectrum based on time-of-flight and pulse-height analysis of single particle events detected through repetitive experiments. With a novel arrangement of multiple scintillators with different ions stopping powers, PCA offers potential advantages over commonly used diagnostic instruments (CR-39, radiochromic films, Thomson parabola, etc.

View Article and Find Full Text PDF

In order to increase the count rate capability of a neutron detection system as a whole, we propose a multi-stage neutron detection system. Experiments to test the effectiveness of this concept were carried out on Fusion Neutronics Source. Comparing four configurations of alignment, it was found that the influence of an anterior stage on a posterior stage was negligible for the pulse height distribution.

View Article and Find Full Text PDF

Strontium isotopes, (89)Sr and (90)Sr, and (226)Ra being radiotoxic when ingested, are routinely monitored in milk and drinking water samples collected from different regions in Canada. In order to monitor environmental levels of activity, a novel semi-automated sensitive method has been developed at the Radiation Protection Bureau of Health Canada (Ottawa, Canada). This method allows the separation and quantification of both (89)Sr and (90)Sr and has also been adapted to quantify (226)Ra during the same sample preparation procedure.

View Article and Find Full Text PDF