A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Percutaneous Bone-Anchored Hearing Implant: Is It Clinically Useful in Korean? | LitMetric

Percutaneous Bone-Anchored Hearing Implant: Is It Clinically Useful in Korean?

J Korean Med Sci

Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.

Published: June 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The aim of this study is to investigate the clinical effectiveness of Ponto in Korea, a recently released percutaneous bone-anchored hearing implant.

Methods: 16 patients with single-sided deafness (SSD) and mixed or conductive hearing loss who underwent Ponto implantation from December 2018 to September 2020 were enrolled in the study. Puretone audiometry, the Korean version of the Hearing in Noise Test (K-HINT), sound localization test (SLT), and Pupillometry were performed pre- and three months post-operation. Standardized questionnaires, the Hearing Handicap Inventory for the Elderly (HHIE) and Speech, Spatial and Qualities of Hearing Scale (SSQ), were administered.

Results: The mean age of subjects was 55.5 (range, 48-67) years. Four males and 12 females participated in the study. The mean puretone average was 73.17 dB hearing level (HL) before surgery and significantly improved to 36.72 dB HL three months after surgery. The mean word recognition score improved from 26.0% to 90.75% after implantation. In the case of K-HINT, there was a significant difference in summation (Z = -2.250, = 0.024) and head shadow effects (Z = -3.103, = 0.002). There was no significant difference in root mean square error degree (RMSE) and hemifield identification scores for SLT testing. Pupillometry was performed to measure listening effort and the results revealed that the degree of pupillary dilatation decreased under the condition of quiet, 0 dB signal to noise ratio (SNR) and 3 dB SNR. The total score for HHIE decreased significantly ( = -3.130, = 0.002) while the SSQ score increased significantly ( = -2.216, = 0.027).

Conclusions: The Ponto bone-anchored hearing system showed significant clinical benefit in Korean patients with conductive and mixed hearing loss and SSD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9194490PMC
http://dx.doi.org/10.3346/jkms.2022.37.e182DOI Listing

Publication Analysis

Top Keywords

bone-anchored hearing
12
hearing
9
percutaneous bone-anchored
8
hearing loss
8
study puretone
8
pupillometry performed
8
three months
8
hearing implant
4
implant clinically
4
clinically korean?
4

Similar Publications