Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Interstitial cells of Cajal (ICCs) function as pacemaker cells in the gastrointestinal tract. Acute thoracic trauma is a common and lethal cause of death due to physical trauma caused by traffic accidents. This study aimed to explore the distribution of esophageal ICCs and distribution changes observed after acute thoracic trauma. Thirty rabbits were randomly divided into a control group and two study groups. The control group animals underwent an esophagectomy. All animals in the study groups underwent right chest puncture using the Hopkinson bar technique. The study groups were subjected to esophagectomy 24 and 72 h after chest puncture. Distribution, morphology, and density of esophageal ICCs were detected using transmission electron microscopy, toluidine blue staining, and immunohistochemistry. Apoptosis of esophageal ICCs was evaluated using the terminal deoxynucleotidyl transferase (TdT) dUTP Nick-End Labeling assay. Western blotting and reverse transcription polymerase chain reaction were used to detect changes in the SCF/c-kit signaling pathway. Esophageal ICCs distribution and SCF/c-kit signal pathway decreased from the upper part to the lower part in both physiological state and after thoracic trauma. In contrast, death of ICCs increased from the upper part to the lower part, both in physiological and injured state (P < 0.05). After thoracic trauma, increased ICCs and decreased death of ICCs in all parts of the esophagus (P < 0.05) were observed. The observed distribution and changes in esophageal ICCs would have an impact on motility and motility disorders of the esophagus.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10735-022-10074-wDOI Listing

Publication Analysis

Top Keywords

thoracic trauma
16
esophageal iccs
16
study groups
12
interstitial cells
8
cells cajal
8
acute thoracic
8
iccs distribution
8
control group
8
chest puncture
8
upper lower
8

Similar Publications

Management of Transvenous Leads in Patients With Iatrogenic Lead Perforation.

J Cardiovasc Electrophysiol

September 2025

Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.

Introduction: Iatrogenic lead perforation is a rare but serious complication of cardiac implantable electronic device (CIED) implantation. Evidence on percutaneous management of subacute or delayed cases remains limited.

Methods: We retrospectively reviewed 38 patients treated for iatrogenic lead perforation between January 2012 and October 2024.

View Article and Find Full Text PDF

Background: There is conflicting literature regarding mortality outcomes associated with REBOA usage in patients with severe thoracic or abdominal trauma. Our study aims to assess the benefits and negative implications of REBOA use in adult trauma patients in hemorrhagic shock with severe thoracic or abdominal injuries.

Methods: This retrospective cohort analysis utilized the American College of Surgeons Trauma Quality Improvement Program Participant Use File (ACS-TQIP-PUF) database from 2017 to 2023 to evaluate adult patients with severe isolated thoracic or abdominal trauma undergoing REBOA placement.

View Article and Find Full Text PDF

Delayed hemothorax (DHTX) is a possible sequelae of thoracic trauma, especially in the setting of patients being treated with anticoagulation. We report the case of an 81-year-old Caucasian man with a DHTX presenting 14 days following an initial emergency department (ED) visit with multiple rib fractures due to a fall from the patient's bed. Upon presentation to the ED a second time, the patient was hospitalized, tested positive for COVID-19, and on the second day of admission underwent video-assisted thoracoscopic surgery (VATS) without bleeding or other complications.

View Article and Find Full Text PDF

The cervicothoracic junction (CTJ) presents a surgical challenge due to its transitional nature from mobile to rigid segments. Therefore, the biomechanical characteristics of this transitional zone must be taken into consideration during instrumentation. This study aimed to determine the efficacy of the cervical pedicle screw placement (CPS) combined with 5.

View Article and Find Full Text PDF

Thoracic aortic injury as a complication of spinal surgery: A new case and systematic review (1991-2024).

J Vasc Surg Cases Innov Tech

December 2025

Faculdade de Ciências Médicas de Alagoas, Vascular and Endovascular Surgery Division, Alagoas, Alagoas, Brazil.

Background: Iatrogenic thoracic aortic injury (TAI) is a rare but well-recognized complication of spine surgery, lacking standardized treatment guidelines due to its rarity and variability of manifestations.

Methods: We present a new case of TAI successfully managed with endovascular repair and systematically reviewed 52 articles (1991-2024) reporting 64 cases, including demographics, surgical indications, injury patterns, and treatments.

Results: A 53-year-old man with a T7 fracture underwent posterior spinal instrumentation and developed chest pain due to a combination of impingement and screw penetration into the thoracic aorta and was treated with thoracic endovascular aortic repair (TEVAR) and removal of pedicle screws.

View Article and Find Full Text PDF