A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Flash glucose monitoring system in special situations. | LitMetric

Flash glucose monitoring system in special situations.

Arch Endocrinol Metab

Departamento de Clínica Médica, Universidade Federal de Santa Catarina, Florianópolis, SC, Brasil.

Published: November 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The management of diabetes mellitus (DM) requires maintaining glycemic control, and patients must keep their blood glucose levels close to the normal range to reduce the risk of microvascular complications and cardiovascular events. While glycated hemoglobin (A1C) is currently the primary measure for glucose management and a key marker for long-term complications, it does not provide information on acute glycemic excursions and overall glycemic variability. These limitations may even be higher in some special situations, thereby compromising A1C accuracy, especially when wider glycemic variability is expected and/or when the glycemic goal is more stringent. To attain adequate glycemic control, continuous glucose monitoring (CGM) is more useful than self-monitoring of blood glucose (SMBG), as it is more convenient and provides a greater amount of data. Flash Glucose Monitoring (isCGM /FGM) is a widely accepted option of CGM for measuring interstitial glucose levels in individuals with DM. However, its application under special conditions, such as pregnancy, patients on hemodialysis, patients with cirrhosis, during hospitalization in the intensive care unit and during physical exercise has not yet been fully validated. This review addresses some of these specific situations in which hypoglycemia should be avoided, or in pregnancy, where strict glycemic control is essential, and the application of isCGM/FGM could alleviate the shortcomings associated with poor glucose control or high glycemic variability, thereby contributing to high-quality care.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10118756PMC
http://dx.doi.org/10.20945/2359-3997000000479DOI Listing

Publication Analysis

Top Keywords

glucose monitoring
12
glycemic control
12
glycemic variability
12
flash glucose
8
special situations
8
glycemic
8
blood glucose
8
glucose levels
8
glucose
7
monitoring system
4

Similar Publications