Article Abstract

Background: Correction of valvular disease is often undertaken during left ventricular assist device (LVAD) implantation with uncertain benefit. We analyzed clinical outcomes with HeartMate 3 (HM3; Abbott) LVAD implantation in those with various concurrent valve procedures (HM3+VP) with those with an isolated LVAD implant (HM3 alone).

Methods: The study included 2200 patients with HM3 implanted within the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) trial portfolio who underwent 820 concurrent procedures among which 466 (21.8%) were HM3+VP. VPs included 101 aortic, 61 mitral, 163 tricuspid; 85 patients had multiple VPs. Perioperative complications, major adverse events, and survival were analyzed.

Results: Patients who underwent HM3+VP had higher-acuity Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profiles (1-2: 41% vs 31%) compared with no VPs (P < .05). The cardiopulmonary bypass time (124 vs 76 minutes; P < .0001) and hospital length of stay (20 vs 18 days; P < .0001) were longer in HM3+VP. A higher incidence of stroke (4.9% vs 2.4%), bleeding (33.9% vs 23.8%), and right heart failure (41.5% vs 29.6%) was noted in HM3+VP at 0 to 30 days (P < .01), with no difference in 30-day mortality (3.9% vs 3.3%) or 2-year survival (81.7% vs 80.8%). Analysis of individual VP showed no differences in survival compared to HM3 alone. No differences were noted among patients with either significant mitral (moderate or worse) or tricuspid (moderate or worse) regurgitation with or without corrective surgery.

Conclusions: Concurrent VPs, commonly performed during LVAD implantation, are associated with increased morbidity during the index hospitalization, with no effect on short- and long-term survival. There is sufficient equipoise to consider a randomized trial on the benefit of commonly performed VPs (such as mitral or tricuspid regurgitation correction), during LVAD implantation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2022.04.021DOI Listing

Publication Analysis

Top Keywords

circulatory support
12
left ventricular
8
ventricular assist
8
assist device
8
multicenter study
8
study maglev
8
maglev technology
8
technology patients
8
patients undergoing
8
undergoing mechanical
8

Similar Publications

Aims: Non-pharmacological therapies for acute decompensated heart failure (HF) and cardiogenic shock have evolved considerably in recent decades. Short-term mechanical circulatory support (MCS) devices can be used as circulatory backup. While nearly all available devices use continuous flow, evidence indicates that pulsatile flow can be more effective.

View Article and Find Full Text PDF

Long-distance aeromedical transport of critically ill patients is an increasingly important component of modern intensive care. However, the combination of veno-arterial extracorporeal membrane oxygenation (VA ECMO) and renal replacement therapy (RRT) during an intercontinental flight had never been previously documented. This case report describes the first known case of a 27 year old patient with fulminant viral myocarditis and multi-organ failure who was successfully repatriated from Bangkok (Thailand) to Paris (France) while receiving both VA ECMO and 6 hours of in-flight sustained low-efficiency dialysis (SLED).

View Article and Find Full Text PDF

Introduction: Sepsis remains a leading cause of mortality, with mortality from septic shock exceeding 40%. Standardized resuscitation (30 mL/kg) may cause adverse outcomes, including fluid overload or prolonged hypotension, emphasizing the need for individualized strategies. Sepsis-induced shock arises from varying degrees of vasodilation and hypovolemia, yet patients often present with similar clinical signs in the emergency department (ED).

View Article and Find Full Text PDF

Distribution of nailfold videocapillaroscopy parameters in systemic lupus erythematosus and their association with disease activity: an international blinded case-control analysis on behalf of the EULAR study group on microcirculation in rheumatic diseases.

RMD Open

September 2025

Department of Rheumatology and Department of Internal Medicine, Ghent University Hospital, Unit for Molecular Immunology and Inflammation, Flemish Institute for Biotechnology, Inflammation Research Center, University of Ghent, Ghent, Belgium.

Objectives: To evaluate whether patients with systemic lupus erythematosus (SLE) have different nailfold videocapillaroscopy (NVC) findings compared with healthy controls (HCs) and whether there is an association between NVC abnormalities and disease activity, clinical and/or laboratory features in SLE.

Methods: This is an observational, multicentre, international, matched case-control study. 381 subjects (203 patients with SLE and 178 HCs) were enrolled from 16 centres in 10 countries.

View Article and Find Full Text PDF

Background: Inflammatory injury in organ donors, particularly after brain death and during ischemia-reperfusion, contributes to graft dysfunction, rejection, and reduced survival. Statins, beyond their lipid-lowering role, exert pleiotropic anti-inflammatory and immunomodulatory effects, including IL-6 suppression, NF-κB inhibition, immune cell modulation, and potential alteration of exosome secretion.

Methods: Building upon this background, this narrative review synthesises preclinical and clinical evidence on pre-donation statin therapy in solid organ transplantation.

View Article and Find Full Text PDF