Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
As DNA polymerases are even active at ambient temperature, there is inevitable non-specific amplification; to avoid the undesired amplification of analytes, a heat activation-based polymerase chain reaction (PCR), called hot-start PCR, is widely used to be highly precise and quantitative in detection. Unlike thermocycling amplification, isothermal amplification, compatible for point-of-care (PoC) tests, cannot be benefited by the heat-activation technique, making the method qualitative rather than quantitative. In this work, we newly developed a lead ion (Pb) activation technique, called lead-start isothermal amplification, allowing on-demand activation or deactivation of DNA polymerases at room temperature. We systematically correlated the DNA polymerase inhibition by the TQ30 aptamer with Pb-responsive strand cleavage by the GR5 DNAzyme, and relying on the type of interconnectors, Pb successfully served as an initiator or a terminator of isothermal DNA amplification. Our lead-start isothermal amplification was exceptionally Pb-specific, dramatically increasing the enzymatic activity of DNA polymerase (>25 times) only by Pb introduction. Despite one-by-one sample preparation, a number of reactions can begin and end at the same time, sharing the identical amplification conditions, and thereby allowing their quantitative analysis and comparison. Using a portable UV lamp and a smartphone camera, we also succeeded in quantifying the amounts of clinically important and human papillomavirus type 16 genes in human serum and SARS-CoV-2's nucleocapsid genes in human serum and saliva, and the limit of detection was as low as 0.1 nM, highly applicable for actual PoC tests in the field with no purification process.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d1nr07894a | DOI Listing |