A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Stress fracture after implant removal from the tibia reconstructed by the induced membrane technique: A case report. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The induced membrane technique promotes vascularization and corticalization of the grafted bone and has become one of the mainstays in treatment of segmental bone defects. However, there are clinical concerns regarding the quality of bony consolidation using the induced membrane technique including a thin cortex formation and cortical notching after consolidation. We present the case of a tibial stress fracture in the bone reconstructed by the induced membrane technique after implant removal.

Case: A 49-year-old male presented post-traumatic osteomyelitis of the right tibia and was treated with staged segmental bone resection leading to an 11 cm defect which was reconstructed using the induced membrane technique. The patient requested implant removal at 33 months after bony consolidation. Four months after implant removal, he developed acute, atraumatic leg pain due to a tibial stress fracture caused by small notching in the reconstructed tibial segment. His stress fracture treated with intramedullary nailing and later healed uneventfully.

Conclusion: Caution is warranted prior to implant removal from bone reconstructed by the induced membrane technique as cortical notching may result in stress fractures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9092251PMC
http://dx.doi.org/10.1016/j.tcr.2022.100647DOI Listing

Publication Analysis

Top Keywords

induced membrane
24
membrane technique
24
stress fracture
16
implant removal
16
reconstructed induced
16
segmental bone
8
bony consolidation
8
cortical notching
8
tibial stress
8
bone reconstructed
8

Similar Publications