Article Abstract

Background: After multiple uncovered self-expandable metal stent (UCSEMS) deployments, endoscopic revision becomes complex and potentially challenging. A novel stent delivery system with a dilation function has recently been developed in Japan. This study evaluated the technical feasibility of this device for patients with unresectable malignant hilar biliary obstruction (MHO) after multiple UCSEMS deployments.

Method: Participants comprised consecutive patients with unresectable MHO who had undergone multiple UCSEMS deployments and required endoscopic revision for the right or left hepatic bile ducts, as decided by cholangiography under endoscopic retrograde cholangiopancreatography (ERCP) guidance.

Results: A total of 14 patients requiring endoscopic revision of right and left hepatic bile ducts were enrolled in this study. Among these 14 patients, guidewire insertion through the mesh of previously placed stents failed in 2 patients. As a result, these two patients underwent only unilateral UCSEMS deployment. Because clinical success was not obtained, transmural placement of the UCSEMS under Endoscopic Ultrasound (EUS) guidance to the segment of the liver not being drained was performed in those patients. The molting technique was attempted in 12 patients, proving successful in all patients. The technical success rate was therefore 92.8% (12/14). Mean procedure time was 23.2 min.

Conclusion: This novel stent delivery system with a dilation function may be useful in endoscopic revision techniques for bilateral UCSEMS deployment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9058454PMC
http://dx.doi.org/10.1177/17562848211062803DOI Listing

Publication Analysis

Top Keywords

endoscopic revision
16
patients
9
metal stent
8
molting technique
8
ucsems deployments
8
novel stent
8
stent delivery
8
delivery system
8
system dilation
8
dilation function
8

Similar Publications

BACKGROUND Atrial septal defect (ASD) occluder devices present a novel approach for managing persistent gastric leaks following sleeve gastrectomy. While sleeve gastrectomy is effective, postoperative leak rates reach up to 3% in primary surgeries and exceed 10% in revisions, with management remaining complex and non-standardized. CASE REPORT This case report describes a 20-year-old Saudi woman who developed a gastric leak after laparoscopic sleeve gastrectomy.

View Article and Find Full Text PDF

The Lyon Consensus 2.0, published in 2023, provides an updated diagnostic framework for gastroesophageal reflux disease (GERD), emphasizing objective physiological testing and introducing the concept of "actionable GERD" to guide individualized therapy. This review evaluates the clinical applicability of this framework in Asia, where normative values require regional adaptation.

View Article and Find Full Text PDF

Background: Gastric cancer (GC) remains a major global health problem. Despite a decline in its incidence, GC is still the third most lethal cancer worldwide.

Background: Multimodal treatment approaches are employed, including chemotherapy (CMT), radiotherapy (RDT), surgery, expanded criteria for endoscopic resection, and increased use of minimally invasive surgery.

View Article and Find Full Text PDF