A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Pulsatile flow in venous perforators of the lower limb. | LitMetric

Pulsatile flow in venous perforators of the lower limb.

Am J Physiol Regul Integr Comp Physiol

Department of Surgical Sciences, Dunedin School of Medicine, University of Otago, Dunedin, New Zealand.

Published: July 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Teaching traditionally asserts that the arterial pressure pulse is dampened across the capillary bed to the extent that pulsatility is nonexistent in the venous circulation of the lower limbs. Herein, we present evidence of transmission of arterial pulsations across the capillary network into perforator veins in the lower limbs of healthy, heat-stressed humans. Perforator veins are connections from the superficial veins that drain into the deep veins. When assessed using ultrasound at rest, they infrequently demonstrate flow, and a pulsatile flow waveform is not described. We investigated perforator vein pulsatility in 10 young, healthy volunteers who underwent passive heating by +2°C core body temperature via a hot-water-perfused suit, and 5 who also underwent active heating by +2°C via low-intensity cycling while wearing the hot-water-perfused suit. At +0.5°C increments in temperature, blood velocity in an ankle perforator vein was measured using duplex ultrasound. In all perforators with heating, sustained flow was demonstrated, with a pulsatile waveform that was synchronous with the cardiac cycle. The maximum velocity was 30 ± 13 cm/s with passive heating and approximately half with active heating ( = 0.04). The small veins of the skin at the ankle also demonstrated increased perfusion with pulsatility, seen with low-velocity microvascular imaging technology. We consider explanations for this pulsatility and conclude that it is propagated from the arterial inflow through the skin microcirculation as a result of increased dilatation and flow volume and that this is a normal response to increased skin blood flow.

Download full-text PDF

Source
http://dx.doi.org/10.1152/ajpregu.00013.2022DOI Listing

Publication Analysis

Top Keywords

pulsatile flow
8
lower limbs
8
perforator veins
8
perforator vein
8
passive heating
8
heating +2°c
8
hot-water-perfused suit
8
active heating
8
veins
5
flow
5

Similar Publications