Direct Use of a Saliva-Collected Cotton Swab in Lateral Flow Immunoassay for the Detection of Cotinine.

Biosensors (Basel)

Department of Chemistry, School of Physics and Chemistry, Gwangju Institute of Science and Technology, Gwangju 61005, Korea.

Published: April 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The detection of salivary cotinine is useful for convenient smoking tests in spite of the high background effect of saliva. For precise results, the conventional salivary cotinine analysis for smoking detection requires complex pretreatment processes. Hence, in this study, we developed a modified paper-based lateral flow immunoassay (LFIA), termed "gap-LFIA", for the direct application of saliva collected using cotton swabs for on-site detection. The gap-LFIA was constructed by modifying a conventional LFIA sensor, where the sample pad was divided to have a 3 mm gap. A saliva-collected cotton swab was inserted into the gap, and then, a buffer solution was added to the outer sample pad to dilute the saliva automatically. The gap-LFIA reduced the interference in salivary samples and showed improved signals, allowing for using the whole saliva directly without additional steps. Further, the deviation of results using a strip was less than that when the saliva was not diluted in a conventional cotinine kit, and it helped to distinguish between smokers and non-smokers more clearly in 15 min. This method of automatic dilution may apply to various clinical samples, including blood and serum, for direct application in future detections.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9029424PMC
http://dx.doi.org/10.3390/bios12040214DOI Listing

Publication Analysis

Top Keywords

saliva-collected cotton
8
cotton swab
8
lateral flow
8
flow immunoassay
8
salivary cotinine
8
direct application
8
sample pad
8
saliva
5
direct saliva-collected
4
swab lateral
4

Similar Publications

Unlabelled: Basis of acute pharyngitis pathogenesis is an inflammatory process at the entrance gate of the infection. Therefore, local immunity study proves to be the most informative. Difficulty in making that type of assessment is lack of generally accepted reference values and biological sampling techniques.

View Article and Find Full Text PDF

The detection of salivary cotinine is useful for convenient smoking tests in spite of the high background effect of saliva. For precise results, the conventional salivary cotinine analysis for smoking detection requires complex pretreatment processes. Hence, in this study, we developed a modified paper-based lateral flow immunoassay (LFIA), termed "gap-LFIA", for the direct application of saliva collected using cotton swabs for on-site detection.

View Article and Find Full Text PDF

Performance of at-home self-collected saliva and nasal-oropharyngeal swabs in the surveillance of COVID-19.

J Oral Microbiol

December 2020

Laboratory of Virology (LIM-52), Institute of Tropical Medicine of São Paulo, School of Medicine, University of São Paulo, São Paulo, Brazil.

: SARS-CoV-2 quickly spreads in the worldwide population, imposing social restrictions to control the infection, being the massive testing another essential strategy to break the chain of transmission. : To compare the performance of at-home self-collected samples - saliva and combined nasal-oropharyngeal swabs (NOP) - for SARS-CoV-2 detection in a telemedicine platform for COVID-19 surveillance. : We analyzed 201 patients who met the criteria of suspected COVID-19.

View Article and Find Full Text PDF

Effect of food contamination and collection material in the measurement of biomarkers in saliva of horses.

Res Vet Sci

April 2020

Interdisciplinary Laboratory of Clinical Analysis (Interlab-UMU), Veterinary School, Campus of Excellence Mare Nostrum, University of Murcia, Campus Espinardo, 30100 Murcia, Spain. Electronic address:

This study aims to evaluate the effect of the presence of food and the material used in a panel of biomarkers in saliva of horses. For the food effect study, clean saliva was incubated with a known amount of food consisting of oats, hay or grass. Significant changes were observed when saliva was incubated with oats for total protein (P = .

View Article and Find Full Text PDF

Uric acid (UA) is the most abundant antioxidant compound in saliva and one of the most sensitive biomarkers for detecting changes in the oxidative status of the organism. The aim of this study was to evaluate the effect of: (i) different methods of saliva sampling and (ii) the correction by salivary flow or total protein on UA concentrations in saliva. Paired saliva (collected by two different methods, passive drooling and using Salivette cotton rolls) and serum samples were obtained from 12 healthy men after the performance of two resistance training exercises of different level of effort that can produce different concentrations in UA in saliva.

View Article and Find Full Text PDF