Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: The ADC of brain tissue slightly varies over the cardiac cycle. This variation could reflect physiology, including mixing of the interstitial fluid, relevant for brain waste clearance. However, it is known from cardiac diffusion imaging that tissue deformation by itself affects the magnitude of the MRI signal, leading to artificial ADC variations as well. This study investigates to what extent tissue deformation causes artificial ADC variations in the brain.

Theory And Methods: We implemented a high-field MRI sequence with stimulated echo acquisition mode that simultaneously measures brain tissue deformation and ADC. Based on the measured tissue deformation, we simulated the artificial ADC variation by combining established theoretical frameworks and compared the results with the measured ADC variation. We acquired data in 8 healthy volunteers with diffusion weighting b = 300 and b = 1000 s/mm .

Results: Apparent diffusion coefficient variation was largest in the feet-to-head direction and showed the largest deviation from the mean ADC at peak systole. Artificial ADC variation estimated from tissue deformation was 1.3 ± 0.37·10  mm /s in the feet-to-head direction for gray matter, and 0.75 ± 0.29·10  mm /s for white matter. The measured ADC variation in the feet-to-head direction was 5.6·10  ± 1.5·10  mm /s for gray matter and 3.2·10  ± 1.0·10  mm /s for white matter, which was a factor of 3.5 ± 0.82 and 3.4 ± 0.57 larger than the artificial diffusion variations. The measured diffusion variations in the right-to-left/anterior-to-posterior direction were a factor of 1.5 ± 1.0/1.7 ± 1.4 and 2.0 ± 0.91/2.5 ± 0.94 larger than the artificial diffusion variations for gray matter and white matter, respectively.

Conclusion: Apparent diffusion coefficient variations in the brain likely largely reflect physiology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9315037PMC
http://dx.doi.org/10.1002/mrm.29209DOI Listing

Publication Analysis

Top Keywords

tissue deformation
20
artificial adc
16
adc variation
16
adc variations
12
feet-to-head direction
12
gray matter
12
white matter
12
diffusion variations
12
adc
10
cardiac cycle
8

Similar Publications

Histological preparation paraffin embedding is the gold standard method for evaluating tissue structure and composition, whether it is originated from biopsy or engineered . Quite often, deformation and shrinkage occur during the histological preparation, which are difficult to predict and qualify. The present study investigates the morphometric changes in bioprinted hydrogels composed of alginate and gelatine, common tissue engineering materials, focusing on three morphologies: full slabs, porous slabs, and porous cubes.

View Article and Find Full Text PDF

Time-dependent post-mortem histomorphological changes in Penaeus vannamei following humane euthanasia.

Vet Res Commun

September 2025

Centro de Investigación en Alimentación y Desarrollo, A.C. Subsede Mazatlán en Acuicultura y Manejo Ambiental, Av. Sábalo-Cerritos S/N, Mazatlán 82112, Sinaloa, México.

Histological analysis is a method commonly used in medical clinics to evaluate biological tissues and their abnormalities. However, this method is based on tissue collected from the necropsy of the animal, where modifications in the tissue associated with autolysis can occur after death. This study analyses the post-mortem histomorphological changes in white shrimp (Penaeus vannamei) after euthanasia by clove oil anaesthesia induction and pithing as a secondary killing method.

View Article and Find Full Text PDF

In this article, a biophysically realistic model of a soft octopus arm with internal musculature is presented. The modeling is motivated by experimental observations of sensorimotor control where an arm localizes and reaches a target. Major contributions of this article are: (i) development of models to capture the mechanical properties of arm musculature, the electrical properties of the arm peripheral nervous system (PNS), and the coupling of PNS with muscular contractions; (ii) modeling the arm sensory system, including chemosensing and proprioception; and (iii) algorithms for sensorimotor control, which include a novel feedback neural motor control law for mimicking target-oriented arm reaching motions, and a novel consensus algorithm for solving sensing problems such as locating a food source from local chemical sensory information (exogenous) and arm deformation information (endogenous).

View Article and Find Full Text PDF

Background Elevated brain iron is a potential marker for neurodegeneration, but its role in predicting onset of mild cognitive impairment (MCI) and prospective cognitive trajectories remains unclear. Purpose To investigate how brain iron and amyloid-β (Aβ) levels, measured using quantitative susceptibility mapping (QSM) MRI and PET, help predict MCI onset and cognitive decline. Materials and Methods In this prospective study conducted between January 2015 and November 2022, cognitively unimpaired older adults underwent baseline QSM MRI.

View Article and Find Full Text PDF

Wearable bioelectronics have advanced dramatically over the past decade, yet remain constrained by their superficial placement on the skin, which renders them vulnerable to environmental fluctuations and mechanical instability. Existing microneedle (MN) electrodes offer minimally invasive access to dermal tissue, but their rigid, bulky design-often 100 times larger and 10,000 times stiffer than dermal fibroblasts-induces pain, tissue damage, and chronic inflammation, limiting their long-term applicability. Here, a cell-stress-free percutaneous bioelectrode is presented, comprising an ultrathin (<2 µm), soft MN (sMN) that dynamically softens via an effervescent structural transformation after insertion.

View Article and Find Full Text PDF