Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: To evaluate the difference between CT examinations using 240 mgI/mL contrast material (CM) and 320 mgI/mL CM in the contrast enhancement of the abdominal organs and the diagnostic performance for focal hepatic lesions. Materials and methods: This retrospective study included 422 CT examinations, using 240 mgI/mL iohexol (Group A, 206 examinations) and 320 mgI/mL ioversol (Group B, 216 examinations), performed between April 2019 and May 2020. Two CT scanners (single-source CT (machine A) and dual-source CT (machine B)) were used to obtain CT images. Two radiologists independently drew regions of interest (ROIs) in the liver, pancreas, spleen, kidney, aorta, portal vein, and paraspinal muscle. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for each organ. They evaluated the degree of subjective enhancement of the organs and detected/differentiated focal hepatic lesions. Results: The SNR, CNR, and subjective enhancement of most organs were significantly higher in Group B than in Group A (p < 0.05). The sensitivity and specificity for cysts and malignancy were higher than 85.0% in both groups. The sensitivity for hemangioma was lower in Group B (<75%) than in Group A. In Group A, the SNR and CNR were significantly higher in most organs with machine B than with machine A. Conclusion: Although the SNR and CNR of the abdominal organs were lower with 240 mgI/mL CM than with 320 mgI/mL CM, 240 mgI/mL CM was feasible for evaluating the liver. A CT scanner with more advanced specifications may be beneficial for examinations with 240 mgI/mL CM by using lower tube voltage.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8947528 | PMC |
http://dx.doi.org/10.3390/diagnostics12030752 | DOI Listing |