98%
921
2 minutes
20
Background: The location of retinal vessels is an important prerequisite for Central Serous Chorioretinopathy (CSC) Laser Surgery, which does not only assist the ophthalmologist in marking the location of the leakage point (LP) on the fundus color image but also avoids the damage of the laser spot to the vessel tissue, as well as the low efficiency of the surgery caused by the absorption of laser energy by retinal vessels. In acquiring an excellent intra- and cross-domain adaptability, the existing deep learning (DL)-based vessel segmentation scheme must be driven by big data, which makes the densely annotated work tedious and costly.
Methods: This paper aims to explore a new vessel segmentation method with a few samples and annotations to alleviate the above problems. Firstly, a key solution is presented to transform the vessel segmentation scene into the few-shot learning task, which lays a foundation for the vessel segmentation task with a few samples and annotations. Then, we improve the existing few-shot learning framework as our baseline model to adapt to the vessel segmentation scenario. Next, the baseline model is upgraded from the following three aspects: (1) A multi-scale class prototype extraction technique is designed to obtain more sufficient vessel features for better utilizing the information from the support images; (2) The multi-scale vessel features of the query images, inferred by the support image class prototype information, are gradually fused to provide more effective guidance for the vessel extraction tasks; and (3) A multi-scale attention module is proposed to promote the consideration of the global information in the upgraded model to assist vessel localization. Concurrently, the integrated framework is further conceived to appropriately alleviate the low performance of a single model in the cross-domain vessel segmentation scene, enabling to boost the domain adaptabilities of both the baseline and the upgraded models.
Results: Extensive experiments showed that the upgraded operation could further improve the performance of vessel segmentation significantly. Compared with the listed methods, both the baseline and the upgraded models achieved competitive results on the three public retinal image datasets (i.e., CHASE_DB, DRIVE, and STARE). In the practical application of private CSC datasets, the integrated scheme partially enhanced the domain adaptabilities of the two proposed models.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8927682 | PMC |
http://dx.doi.org/10.3389/fmed.2022.821565 | DOI Listing |
Interv Neuroradiol
September 2025
Department of Neurosurgery, Shinshu University School of Medicine, Matsumoto, Japan.
BackgroundA stable guiding system is essential for successful carotid artery stenting (CAS), particularly when navigating tortuous aortic or supra-aortic anatomy. However, data on the mechanical behavior of stent delivery systems remain scarce.ObjectiveTo assess and compare the bending stiffness and trackability of five commercially available carotid stent delivery systems using bench-top experiments.
View Article and Find Full Text PDFSci Prog
September 2025
Faculty of Medicine, Universitas Indonesia, Jakarta, Indonesia.
Single coronary ostium and intramural coronary artery variations in patients with transposition of the great arteries significantly increase the mortality and morbidity after arterial switch operation (ASO). In these patients, the classic coronary button implantation may cause kinking or twisting of the coronary artery which can cause coronary insufficiency. This case series presents two patients, a 15-month-old girl with transposition of the great arteries and a 10-month-old boy with a Taussig-Bing anomaly.
View Article and Find Full Text PDFCan Assoc Radiol J
July 2025
Department of Diagnostic Imaging, Division of Neuroradiology, University of Toronto, Toronto Western Hospital, University Health Network, Toronto, ON, Canada.
Purpose: Accurate vessel measurement is essential in endovascular thrombectomy (EVT) for acute ischemic stroke. Discrepancies between computed tomography angiography (CTA) and digital subtraction angiography (DSA) may impact procedural planning and device selection. This study compares vessel diameter measurements from CTA and DSA in patients with middle cerebral artery (MCA) M1 occlusions.
View Article and Find Full Text PDFTransl Vis Sci Technol
September 2025
Department of Ophthalmology, University of Pittsburgh, School of Medicine, Pittsburgh, Pennsylvania, USA.
Purpose: To evaluate choroidal vasculature using a novel three-dimensional algorithm in fellow eyes of patients with unilateral chronic central serous chorioretinopathy (cCSC).
Methods: Patients with unilateral cCSC were retrospectively included. Automated choroidal segmentation was conducted using a deep-learning ResUNet model.
Cureus
August 2025
Internal Medicine, Shifa International Hospital Islamabad, Islamabad, PAK.
One of the relatively common anatomical variants of coronary vessels that is often overlooked in clinical practice is coronary artery tortuosity (CAT). CAT can have a significant impact on coronary blood flow and procedural outcomes during percutaneous coronary intervention (PCI). It is defined by bends, curves, or loops within the coronary vasculature that can lead to increased vascular resistance.
View Article and Find Full Text PDF