Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
The present study aimed to evaluate the students’ progress in evaluating ultrasound (US) and cadaveric cardiac images and long-time retention of information. First-year medical students were invited to participate in four two-hour online lectures during one week voluntarily. The students were trained to recognize cardiovascular anatomical structures on US and cadaveric images during the intervention. The participants’ abilities to identify specific anatomical structures were tested before, immediately after and six months after the training. A group of second-year students without US training participated as a control group and filled the same test once. Ninety-one first-year students agreed to participate, and forty-nine completed all three tests. The performances in the correct identification of cardiovascular structures on the US images significantly improved after the training but significantly decreased after six months. In the intervention group, the accurate identification of cardiovascular structures was significantly higher on cadaveric images (80% vs. 53%, p-value < 0.0001, n = 91 at post-training; 70% vs. 33%, p-value < 0.0001, n = 49 at 6 months after training). The correct answers percentage score in the control group varied from 6.7% to 66.7% for US cardiovascular anatomical without a significant difference than the intervention group (p-value = 0.7651). First-year students’ knowledge of heart US anatomy proved less effective than cadaveric images, significantly improved after training and decreased over time, indicating the need for repetition reinforcement.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8910278 | PMC |
http://dx.doi.org/10.3390/ijerph19053033 | DOI Listing |