A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Determination of optimal regularization factor in Bayesian penalized likelihood reconstruction of brain PET images using [ F]FDG and [ C]PiB. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: The Bayesian penalized likelihood (BPL) reconstruction algorithm, Q.Clear, can achieve a higher signal-to-noise ratio on images and more accurate quantitation than ordered subset-expectation maximization (OSEM). The reconstruction parameter (β) in BPL requires optimization according to the radiopharmaceutical tracer. The present study aimed to define the optimal β value in BPL required to diagnose Alzheimer disease from brain positron emission tomography (PET) images acquired using F-fluoro-2-deoxy-D-glucose ([ F]FDG) and C-labeled Pittsburg compound B ([ C]PiB).

Methods: Images generated from Hoffman 3D brain and cylindrical phantoms were acquired using a Discovery PET/computed tomography (CT) 710 and reconstructed using OSEM + time-of-flight (TOF) under clinical conditions and BPL + TOF (β = 20-1000). Contrast was calculated from images generated by the Hoffman 3D brain phantom, and noise and uniformity were calculated from those generated by the cylindrical phantom. Five cognitively healthy controls and five patients with Alzheimer disease were assessed using [ F]FDG and [ C]PiB PET to validate the findings from the phantom study. The β values were restricted by the findings of the phantom study, then one certified nuclear medicine physician and two certified nuclear medicine technologists visually determined optimal β values by scoring the quality parameters of image contrast, image noise, cerebellar stability, and overall image quality of PET images from 1 (poor) to 5 (excellent).

Results: The contrast in BPL satisfied the Japanese Society of Nuclear Medicine (JSNM) criterion of ≥55% and exceeded that of OSEM at ranges of β = 20-450 and 20-600 for [ F]FDG and [ C]PiB, respectively. The image noise in BPL satisfied the JSNM criterion of ≤15% and was below that in OSEM when β = 150-1000 and 400-1000 for [ F]FDG and [ C]PiB, respectively. The phantom study restricted the ranges of β values to 100-300 and 300-500 for [ F]FDG and [ C]PiB, respectively. The BPL scores for gray-white matter contrast and image noise, exceeded those of OSEM in [ F]FDG and [ C]PiB images regardless of β values. Visual evaluation confirmed that the optimal β values were 200 and 450 for [ F]FDG and [ C]PiB, respectively.

Conclusions: The BPL achieved better image contrast and less image noise than OSEM, while maintaining quantitative standardized uptake value ratios (SUVR) due to full convergence, more rigorous noise control, and edge preservation. The optimal β values for [ F]FDG and [ C]PiB brain PET were apparently 200 and 450, respectively. The present study provides useful information about how to determine optimal β values in BPL for brain PET imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.15593DOI Listing

Publication Analysis

Top Keywords

f]fdg c]pib
32
optimal values
16
image noise
16
brain pet
12
pet images
12
phantom study
12
nuclear medicine
12
contrast image
12
f]fdg
9
bayesian penalized
8

Similar Publications