Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: To assess how patients' dependent parameters may affect [68Ga]Ga-DOTANOC image quality and to propose a theoretical body mass index (BMI)-adjusted injected activity (IA) scheme, to improve imaging of high weight patients.

Methods: Among patients prospectively enrolled (June-2019 and May-2020) in an Institutional Ethical Committee-approved electronic archive, we included those affected by primary gastro-entero-pancreatic (GEP) or lung neuroendocrine tumour and referred by our Institutional clinicians (excluding even minimal radiopharmaceutical extravasation, movement artefacts, renal insufficiency). All PET/CT images were acquired following EANM guidelines and rated for visual quality (1 = non-diagnostic, 2 = poor, 3 = moderate, 4 = good). Collected data included patient's body mass, height, BMI, age, IA (injected activity), IA/Kg (IAkg), IA/BMI (IABMI), liver SUVmean, liver SUVmax standard deviation, liver-signal-to-noise (LSNR), normalised_LSNR (LSNR_norm) and contrast-to-noise ratio (CNR) for positive scans and were compared to image rating (poor moderate/good).

Results: Overall, 77 patients were included. Rating concordance was high (agreement = 81.8%, Fleiss k score = 0.806). All patients' dependent parameters resulted significantly different between poor-rated and moderate/good-rated scans (IA: = 0.006, IAkg: =< 0.001, body weight: =< 0.001, BMI: =< 0.001, IABMI: =< 0.001). Factors significantly associated with moderate/good rating were BMI ( =< 0.001), body weight ( =< 0.001), IABMI ( =< 0.001), IAkg ( = 0.001), IA ( = 0.003), LSNR_norm ( = 0.01). The BMI-based model presented the best predictive efficiency (81.82%). IABMI performance to differentiate moderate/good from poor rating resulted statistically significant (IA-AUC = 0.78; 95% CI: 0.68-0.89; cut-off value of 4.17 MBq*m/kg, sensitivity = 81.1%, specificity = 66.7%). If BMI-adjusted IA (=4.17*BMI) would have been applied in this population, the median IA would have slightly inferior (-4.8%), despite a different IA in each patient.

Advances In Knowledge: BMI resulted the best predictor of image quality. The proposed theoretical BMI-adjusted IA scheme (4.17*BMI) should yield images of better quality (especially in high-BMI patients) maintaining practical scanning times (3 min/bed).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10996427PMC
http://dx.doi.org/10.1259/bjr.20211152DOI Listing

Publication Analysis

Top Keywords

image quality
12
injected activity
12
bmi-adjusted injected
8
patients' dependent
8
dependent parameters
8
body mass
8
0001
8
iakg 0001
8
0001 body
8
body weight
8

Similar Publications

Objective: To improve B field homogeneity in prostate MR imaging and spectroscopy using a custom-designed 16-channel external local shim coil array.

Methods: In vivo prostate imaging was performed in seven healthy volunteers (mean age: 40.7 years) without bowel preparation.

View Article and Find Full Text PDF

The need to enhance the quality of life and functionality of patients with a number of diseases, such as congenital abnormalities, traumas, and gender incongruence, has contributed to a significant development in the field of male genital reconstructive surgery. This article highlights the roots of penile reconstructive surgeries over history, emphasizing innovative achievements that have shaped modern practices. Critical advancements that have improved surgical accuracy and post-operative care are examined, including new imaging modalities, penile prosthesis implantation, and complete phallic reconstruction.

View Article and Find Full Text PDF

In-line multi-wavelength non-destructive pharma quality monitoring with ultrabroadband carbon nanotubes photo-thermoelectric imaging scanners.

Light Sci Appl

September 2025

Department of Electrical, Electronic, and Communication Engineering, Faculty of Science and Engineering, Chuo University, 1-13-27 Kasuga, Bunkyo-ku, Tokyo, 112-8551, Japan.

While non-destructive in-line monitoring at manufacturing sites is essential for safe distribution cycles of pharmaceuticals, efforts are still insufficient to develop analytical systems for detailed dynamic visualisation of foreign substances and material composition in target pills. Although spectroscopies, expected towards pharma testing, have faced technical challenges in in-line setups for bulky equipment housing, this work demonstrates compact dynamic photo-monitoring systems by selectively extracting informative irradiation-wavelengths from comprehensive optical references of target pills. This work develops a non-destructive in-line dynamic inspection system for pharma agent pills with carbon nanotube (CNT) photo-thermoelectric imagers and the associated ultrabroadband sub-terahertz (THz)-infrared (IR) multi-wavelength monitoring.

View Article and Find Full Text PDF

Background And Objective: While whole-gland therapies for localized prostate cancer (PCa) offer excellent oncological outcomes, these can impact patients' quality of life (QoL) through serious side effects. Focal therapy using high-intensity focused ultrasound (HIFU) has emerged as a less invasive alternative to preserve QoL. However, data on the psychological impact of HIFU remain rare.

View Article and Find Full Text PDF

Background: Hounsfield units (HU) on computed tomography (CT) are strongly correlated with bone mineral density (BMD) and may aid in osteoporosis screening. However, there is no standardized method for assessing bone density in displaced femoral head fractures. This study aimed to measure HU values in the femoral head using preoperative post-fracture CT images of patients with intertrochanteric femoral fractures and investigate whether it correlated with BMD measured by dual-energy X-ray absorptiometry (DXA).

View Article and Find Full Text PDF