A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Functional and Radiological Outcomes after Treatment with Custom-Made Glenoid Components in Revision Reverse Shoulder Arthroplasty. | LitMetric

Functional and Radiological Outcomes after Treatment with Custom-Made Glenoid Components in Revision Reverse Shoulder Arthroplasty.

J Clin Med

Department of Orthopedic Surgery, Ordensklinikum Linz Barmherzige Schwestern, Vinzenzgruppe Center of Orthopedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, 4020 Linz, Austria.

Published: January 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Glenoid implant position and fixation are challenging in severe glenoid defects in reverse total shoulder arthroplasty (rTSA). Custom-made glenoid implants are metal augmented implants that are specially produced for a certain defect. They provide the restoration of the joint line and proper fixation. This retrospective data analysis investigated the clinical and radiological outcomes after revision using custom-made glenoid implants. Between 2018 and 2020, nine patients (10 shoulders) with severe glenoid defects underwent revision rTSA using a custom-made glenoid implant (Materialise Glenius or Lima ProMade). The pre- and postoperative Constant Murley Score (CMS), UCLA Score and Subjective Shoulder Value (SSV) were assessed. Postoperative CT scans and X-rays in two planes were available. The minimum follow-up was 12 months, with a mean follow-up of 23.1 months. The mean preoperative CMS, UCLA Score and SSV were 10.9, 4.1 and 11.0, respectively. The mean postoperative CMS, UCLA Score and SSV showed significant increases of 51.7 (<0.001), 22.9 (<0.001) and 52.0 (<0.001), respectively. There were no signs of loosening implants or scapular notching, and no revision was necessary. This trial showed promising clinical and radiological short-term outcomes for custom-made glenoid components in revision rTSA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8837185PMC
http://dx.doi.org/10.3390/jcm11030551DOI Listing

Publication Analysis

Top Keywords

custom-made glenoid
16
cms ucla
12
ucla score
12
radiological outcomes
8
shoulder arthroplasty
8
glenoid implant
8
severe glenoid
8
glenoid defects
8
rtsa custom-made
8
glenoid implants
8

Similar Publications