A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study. | LitMetric

Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study.

Strategies Trauma Limb Reconstr

Department of Trauma and Orthopaedics, School of Medicine, University of Leeds, Leeds, United Kingdom.

Published: January 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: No entirely reliable method to assess union during Ilizarov treatment exists. Premature frame removal results in treatment failure, and alternative methods of assessment warrant investigation. Wire deflection might provide an indication of fracture site deformation on weight-bearing, indicating progress towards union. A previous study from our group demonstrated this approach may be clinically applicable. We investigated translation of this method into clinical practice in an observational pilot study.

Materials And Methods: Patients with tibial shaft fractures treated with Ilizarov frames were recruited. A prototype depth gauge was used to measure wire deflection on weight-bearing. Investigators undertaking the measurement were blinded to the clinical stage of treatment, and clinicians caring for the patient were blinded to deflection results. Patient records were reviewed at the end of treatment to determine likely fracture stability at each time point. Deflection per kg of weight applied, per mm from the ring was compared between stable and unstable situations.

Results: Thirty-one measurements were obtained in 14 patients. The situation was deemed stable at 13 and unstable at 18 measurements. The median deflection in the stable group was 0.030 microns/kg/mm (IQR 0.005-0.104) and 0.165 microns/kg/mm (IQR 0.072-0.328) in the unstable group. This difference was statistically significant (Wilcoxon Mann-Whitney test = 0.0014). ROC curve analysis revealed that wire deflection was able to predict clinical stability (AUC 0.84, <0.0001). Various technical problems were encountered when using the device which would potentially limit its clinical utility in its current form.

Conclusion: In this set of observations, wire deflection was significantly associated with clinically and radiologically determined stability. Though various practical limitations were encountered in using the prototype measurement device, this proof-of-concept study supports further development of this approach. The research group plan to develop a smaller, more reliable device for further clinical testing in a larger group of patients.

How To Cite This Article: Lineham B, Stewart T, Ward J, Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study. Strategies Trauma Limb Reconstr 2021;16(3):132-137.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8778728PMC
http://dx.doi.org/10.5005/jp-journals-10080-1537DOI Listing

Publication Analysis

Top Keywords

wire deflection
16
union ilizarov
8
stable unstable
8
microns/kg/mm iqr
8
deflection
7
measurement wire
4
deflection loading
4
loading indicate
4
indicate union
4
ilizarov constructs
4

Similar Publications