A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Structural Behavior of Large-Scale Hollow Section RC Beams and Strength Enhancement Using Carbon Fiber Reinforced Polymer (CFRP) Composites. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

An experimental program was conducted to ascertain the efficiency of Carbon Fiber Reinforced Polymer (CFRP) in enhancing the flexural response of hollow section reinforced concrete (RC) beams. Nine beams were tested under four-point bending in three groups. Beams were categorized to reflect the presence or configuration of the CFRP sheet. Each group consisted of three beams: one with a solid section, one with a square 50×50  mm × mm opening and 1 with 100×100  mm × mm opening. Beams in 1st group were tested in as-built conditions. Beams in the 2nd group were strengthened with a single CFRP sheet bonded to their bottom sides. Configuration of CFRP sheet was altered to U-shape applied to the tension side of 3rd group beams. The inclusion of openings, regardless of their size, did not result in degradation of ultimate load and corresponding deflections. However, cracking loads were found to decline as the opening size increased. Regardless of the opening size and CFRP configuration, ultimate loads of beams increased with the application of CFRP. However, this improvement was limited to the debonding and rupture of CFRP in group 2 and 3 beams, respectively. A comparison in the behavior of group 2 and 3 beams revealed that the application of the U-shape CFRP sheet yielded better flexural performance in comparison with the flat-CFRP sheet bonded to the bottom of beams. In the end, In order to further evaluate the economic and performance benefits of these beams, the cost-benefit analysis was also performed. The analysis showed that the feasibility of the hollow section RC beams is more than the solid section RC beams.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8747643PMC
http://dx.doi.org/10.3390/polym14010158DOI Listing

Publication Analysis

Top Keywords

cfrp sheet
16
beams
15
group beams
12
cfrp
9
hollow beams
8
carbon fiber
8
fiber reinforced
8
reinforced polymer
8
polymer cfrp
8
configuration cfrp
8

Similar Publications