Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aims: For patients with typical and atypical atrial flutter (AFL) but without history of atrial fibrillation (AF), the long-term cardiovascular (CV) outcomes after catheter ablation for AFL remain unclear. We compared the long-term all-cause mortality and CV outcomes in patients with AFL receiving catheter ablation compared with the results with medical therapy.

Methods And Results: Atrial flutter patients receiving catheter ablation for typical AFL were identified using the Health Insurance Database, and constituted the 'AFL ablation group'. Patients with typical and atypical AFL but without ablation (AFL without ablation group) were propensity matched to the AFL ablation group. Patients with prior AF diagnosis were excluded. Primary outcomes included all-cause and CV mortality, heart failure (HF) hospitalization, and stroke. The multivariable cox hazards regression model was used to evaluate the hazard ratio (HR) for study outcomes. A total of 3784 AFL patients (1892 patients in each group) was studied. Their mean follow-up durations were 7.85 ± 2.57 years (AFL without ablation group) and 8.31 ± 4.53 years (AFL ablation group). Atrial flutter with ablation patients had lower risks of all-cause mortality (HR: 0.68, P < 0.001), CV deaths (HR: 0.78, P = 0.001), HF hospitalization (HR: 0.84, P = 0.01), and stroke (HR: 0.80, P = 0.01).

Conclusions: Catheter ablation for AFL in patients without prior AF was associated with lower risks of all-cause mortality and CV events compared with AFL patients without ablation during long-term follow-ups.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/euab308DOI Listing

Publication Analysis

Top Keywords

catheter ablation
20
afl ablation
20
atrial flutter
16
all-cause mortality
16
ablation group
16
ablation
13
afl
12
ablation afl
12
afl patients
12
patients
11

Similar Publications

Background: Catheter ablation is beneficial in patients with symptomatic persistent atrial fibrillation (PerAF), and pulsed field ablation (PFA) is a promising energy source to safely and durably create ablation lesions. However, catheter-specific "PFA waveforms and designs" result in effectiveness and safety profiles that are not transferable to other PFA technologies. A head-to-head comparison between the dual-energy, wide-footprint lattice-tip (Sphere-9, Medtronic) and pentaspline PFA catheter (Farawave, Boston Scientific) is not yet available.

View Article and Find Full Text PDF

Guide Tip Damage Due to Rotablation.

JACC Case Rep

September 2025

Department of Cardiovascular Medicine, Okayama University Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan.

Background: The rotational atherectomy system can effectively debulk calcified coronary lesions. However, rare complications specific to that system have been reported.

Case Summary: A 77-year-old man with a heavily calcified lesion in the right coronary artery (RCA) ostium underwent percutaneous coronary intervention in an 8-F system.

View Article and Find Full Text PDF

Aim    To compare the long-term effectiveness of cryoballoon ablation (CBA) and radiofrequency ablation (RFA) in patients with atrial fibrillation (AF).Material and methods    This retrospective single-site study included 597 patients with AF who had undergone CBA (n=241) or RFA (n=356) between 2016 and 2024. The study participants included 355 men (59.

View Article and Find Full Text PDF

Background: In catheter-based radiofrequency ablation (RFA), energy is delivered to heterogeneous thin-walled tissues to induce therapeutic heating. Variations in electrical and mechanical properties of tissue contents have a great effect on outcomes.

Purpose: The objective of this study is to develop models that replicate tissue heterogeneity and visualize ablation zones for effective evaluation and optimization.

View Article and Find Full Text PDF

Introduction: Fluoroless mapping and ablation using a Pentaspline pulsed field ablation catheter has many advantages. This can be achieved using a "tripolar configuration," which enables high-quality electroanatomical maps, improves the ability to localize electrograms (EGMs), and minimizes the use of additional mapping catheters compared to the standard bipolar configuration. We aimed to evaluate the benefits of using a tripolar configuration in fluoroless atrial fibrillation ablation compared to the standard bipolar configuration.

View Article and Find Full Text PDF