Purpose: Radiation protection glasses is a useful tool for dose reduction of eye lens. However, the method to evaluate the dose of eye lens, which is covered with radiation protection glasses in actual radiation management situation, has not been established. We invented the easy-to-use procedure to estimate the dose of eye lens inside of radiation protection glasses for occupationally exposed person using an X-ray shielding material and an additional personal dosimeter for trunk of the body. The objective of this study was to evaluate the feasibility of the new method.
Methods: The radiation field in interventional radiology (IR) was reconstructed. A personal dosimeter was set to the eye position and neck position of medical staff phantom. Each dosimeter was covered by radiation protection glasses or X-ray shielding material, and the 1 cm or 70 mm dose equivalent quantity in the neck position was compared to the 3 mm dose equivalent quantity in the eye position.
Results: The dose equivalent quantity measured inside of X-ray shielding material in the neck position was similar to that of inside radiation protection glasses. Thus, the X-ray attenuation by radiation protection glasses was able to be simulated using the X-ray shielding material.
Conclusion: It was suggested that the dose of eye lens inside of radiation protection glasses could be easily estimated by covering the conventional personal dosimeter for trunk of the body with the X-ray shielding material.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.6009/jjrt.2021_JSRT_77.12.1432 | DOI Listing |
J Radiol Prot
September 2025
Centre for Radiation Protection Research, Stockholm University, Svante Arrheniusväg 20C, 106 91 Stockholm, Sweden.
The System of Radiological Protection (the "System") developed by the International Commission on Radiological Protection (ICRP) is built on nearly a century of efforts of numerous scientists and practitioners working together internationally. It rests on three enduring pillars: science, ethics, and experience. These pillars support the three fundamental principles that shape radiological protection strategies: justification, optimisation, and application of dose limits.
View Article and Find Full Text PDFWien Klin Wochenschr
September 2025
Section Editor (Imaging), Wiener Klinische Wochenschrift, Vienna, Austria.
Radiat Environ Biophys
September 2025
Environmental Physics Department, Institute for Energy Security and Environmental Safety, HUN-REN Centre for Energy Research, Budapest, Hungary.
Variability in radiation-related health risk and genetic susceptibility to radiation effects within a population is a key issue for radiation protection. Besides differences in the health and biological effects of the same radiation dose, individual variability may also affect dose distribution and its consequences for the same exposure. As exposure to radon progeny affects a large population and has a well-established dose-effect relationship, investigating individual variability upon radon exposure may be particularly important.
View Article and Find Full Text PDFBioelectromagnetics
September 2025
Competence Centre of Sleep Medicine, Charité -Universitaetsmedizin Berlin, Berlin, Germany.
A new whole-body exposure facility for a randomized, double-blind, cross-over provocation study investigating possible effects of 50 Hz magnetic field exposure on sleep and markers of Alzheimer's disease has been developed and dosimetrically analyzed. The exposure facility was custom-tailored for the sleep laboratory where the study was carried out and enables magnetic flux densities of up to 30 μT with a maximum field inhomogeneity of less than ± 20%. Exposure is applied fully software-controlled and in a blinded and randomized manner.
View Article and Find Full Text PDFExp Dermatol
September 2025
L'Oréal Research and Innovation, Aulnay sous Bois, France.
As hyperpigmentation can worsen with exposure to ultraviolet (UV) and visible light (VL), sunscreens with well-balanced UVB/UVA protection and VL-blocking pigments are recommended. Assessing efficiency against VL-induced pigmentation is then mandatory. Recently, an in vivo pigmentation assessment allowing a VL protection factor (pVL-PF) determination, and an in vitro predictive method based on transmittance measures were introduced.
View Article and Find Full Text PDF