A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A hybrid model for multipoint real time potency observation in continuous direct compression manufacturing operations. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The ongoing transition from batch to continuous manufacturing offers both challenges and opportunities in the field of oral solid dosage form production. In turn, Process Analytical Technology (PAT) offers a path towards the successful deployment of continuous tablet manufacturing in rotary tablet presses. One promising PAT tool for this endeavour is the NIR-derived potency measurement. However, the high degree of noise in the data may hamper the extraction of useful information. For this reason, this work focused on the implementation of an adaptive Kalman filter algorithm that incorporates and reconciles the potency prediction given by one or more NIR probes with those of a semi-mechanistic compartmental model developed for the application at hand. This approach allowed for more robust concentration estimations. Furthermore, it was observed that potency levels in multiple locations in the studied tablet press (including those in the finished tablets) could be appropriately inferred using a single in-line measurement data stream. This methodology thus opens the door to advanced process control applications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2021.121385DOI Listing

Publication Analysis

Top Keywords

hybrid model
4
model multipoint
4
multipoint real
4
real time
4
potency
4
time potency
4
potency observation
4
observation continuous
4
continuous direct
4
direct compression
4

Similar Publications